Télécharger Imprimer la page

Greenlee HK12ID Manuel D'instructions page 7

Publicité

Operation (cont'd)
Crimping (cont'd)
4. For a UL or cUL classified crimp, complete the
number of crimps specified in the Connector Table
below.
5. For a single crimp, position the connector so the
crimp will be located at the center of the barrel.
For a double crimp, position the connector so two
crimps will be evenly spaced between the connec-
tor marks.
6. Pump the handle to advance the indenter. Continue
to pump the handle until the pressure relief valve
activates.
Note: Pressure relief is indicated by an audible
"pop". The handle load will also drop suddenly to
indicate a complete crimp.
cUL and UL Classified Crimps
Crimps made with the Greenlee HK12ID Dieless Crimping Tool are cUL and UL classified on standard
concentric, compressed, or compact stranded copper and aluminum cable with the connectors listed
here. Refer to the Connector Table for the brand names and model numbers of appropriate connectors
and the number of crimps required.
Connector Table
Copper Connector Type
Copper Splices
Copper Lugs
Number of
Copper Cable Size:
Crimps*
4 AWG to 1000 kcmil
Aluminum Connector Type
Dual-Rated Aluminum Splices
Dual-Rated Aluminum Lugs
Cable Size: 6 AWG to 500 kcmil
Number of
Cable Size: 600 kcmil to 800 kcmil
Crimps*
Cable Size: 1000 kcmil
* When crimping with the HK12ID crimping tool, use the number of crimps listed in this table
instead of the number provided with the connector.
Greenlee / A Textron Company
Anderson Blackburn
Burndy
®
VHSS
CSP
YS-L
VHS
CU
YS
YA, YA-L, YA-2L
CTL
YA-2LN, YA-2N
VHCS
CTL-L
YA-L-TC, YA-L-2TC
VHCL
LCN
YA-2TC, YAZ
YAZ-2N, YAZ-2TC
1
1
1
Anderson Blackburn
Burndy
®
VACS
ASP
YS-A
YA-A
VACL
ATL
YA-A-TN
1
1
1
2
1
1
2
2
2
HK12ID Dieless Crimping Tool
7. Retract the indenter by twisting the pump handle
clockwise in the open position and closing the
handle to activate the release valve. Continue to
hold the pump handle closed to completely retract
the indenter.
8. Lift the latch to open the crimping head and remove
the connector.
9. After completing the last crimp on an aluminum
connector, wipe off the excess oxide inhibitor.
Note: if it is necessary to retract the indenter before a
crimp cycle is complete, raise the pump handle, twist
clockwise, and close the handle to activate the release
valve and retract the indenter.
ILSCO
Panduit
SCSS
CT
SCS
CTL
SCL, SCH
CLN, CLW, CSW
LCAS
CRA, CRB, CRC
LCA
CRA-L, CRB-L
LCB
CRA-2L
LCD, LCC
CRB-2L
LCAN
CRC-2L
1
1
ILSCO
Panduit
AS, ASN
SA
ACL, ACN
2ACL, 2ACN
LAA
ALNS, ALNN
LAB
ALND
1
1
1
2
2
2
7
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
Penn-
T & B
Tyco (AMP)
Union
54506 to 54528
BCU
54806 to 54828
BBCU
1099898-2 to
54106 to 54128
1-1099898-5,
54206 to 54228
BLU
1099899-2 to
54906BE to 54928BE
BBLU
1-1099899-9,
54854BE to 54882BE
1099939-1 to
1-1099939-5
1
1
Penn-
T & B
Union
PIK
60507 to 60584
BCUA
60106 to 60184
BLUA
60230 to 60284
1
1
1
1
2
2
1

Publicité

loading

Ce manuel est également adapté pour: