Maintenance
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from flying
debris or hydraulic oil.
Schedule
Each Operating Day
Before use:
1. Inspect indenter and head for wear or damage such
as cracks, gouges, or chips.
2. Inspect the tool for damage or leaks. If damage is
detected, return the tool to a Greenlee Authorized
Service Center for inspection.
Skin injection hazard:
• Do not use hands to check for
leaks.
• Depressurize the hydraulic system
before servicing.
Oil under pressure easily punctures
skin, causing serious injury, gangrene,
or death. If you are injured by escap-
ing oil, seek medical attention
immediately.
After use:
1. Wipe all tool surfaces clean with a damp cloth and
mild detergent.
2. Place tool in the carrying case. Store in a cool, dry
place.
Monthly
1. Thoroughly clean all surfaces.
2. Check the oil level.
3. Oil the pin joints and metal surfaces that slide.
Annually or After 10,000 Cycles
1. Change the hydraulic oil.
2. Return the tool to a Greenlee Authorized Service
Center for inspection.
Greenlee / A Textron Company
HK12ID Dieless Crimping Tool
Periodic Pressure Relief Valve Check
Pinch points:
Keep hands away from the crimping
tool head when crimping.
Failure to observe this warning could
result in severe injury or death.
The crimping tool's relief valve may require occasional
adjustment. To determine whether this adjustment is
necessary, periodically test the crimping tool with a
Greenlee 50013408 test meter, 50065750 sensor,
and 52024054 adapter (purchased separately).
1. Install the Greenlee 50065750 sensor into the
52024054 adapter, as shown below.
50065750
Sensor
8
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
52024054
Adapter

Publicité