5.1.2 Sensitivity
The microphone sensitivity can be adjusted in four
steps (0 dB, -6 dB, -12 dB or -18 dB).
1) Keep the button SET (6) pressed for approx. 2 sec -
onds until the display shortly shows
the group adjusting mode (group indication , , or
will flash).
2) In the group adjusting mode, press the button SET
twice to go to the adjusting mode for the sensitivity.
The display will shortly show
sensitivity currently adjusted.
Note: To exit the adjusting mode without making an
adjustment, press the button SET repeatedly until the
display shows
operation.
3) Adjust the sensitivity with the arrow buttons in such
a way to obtain an optimum volume level of the
microphone: If the volume is too high, the micro-
phone will distort; in this case, adjust a lower value
with the button
will be a poor signal-noise ratio; in this case, adjust
a higher value with the button
4) Confirm the selection with the button SET.
will be shortly displayed and the unit will go to nor-
mal operation.
5.1.3 REMOSET transmission
The REMOSET function (frequency adjustment of the
transmitter via a radio signal of the receiver) will be
activated/deactivated for the transmitter.
1) Keep the button SET (6) pressed for approx. 2 sec -
onds until the display shortly shows
the group adjusting mode (group indication , , or
will flash).
2) In the group adjusting mode, press the button SET
three times to go to the adjusting mode for the
REMOSET transmission. The display will show:
with the REMOSET function activated
with the REMOSET function deactivated
Note: To exit the adjusting mode without making an
adjustment, press the button SET repeatedly until the
display shows
operation.
3) To deactivate the REMOSET function, press the
button
(8); to activate the REMOSET function,
press the button
4) Confirm the selection with the button SET.
will be shortly displayed and the unit will go to nor-
mal operation.
10
and then the
. The unit will then return to normal
(8). If the volume is too low, there
(7).
. The unit will then return to normal
(7).
5.1.4 Identification number
To allow the REMOSET transmission between the
transmitter and the receiver, the identification numbers
of the units must be matched.
and then
1) Keep the button SET (6) pressed for approx. 2 sec -
onds until the display shortly shows
the group adjusting mode (group indication , , or
will flash).
2) In the group adjusting mode, press the button SET
four times to go to the adjusting mode for the iden-
tification number. The display will show
identification number currently adjusted.
Note: To exit the adjusting mode without making an
adjustment, press the button SET repeatedly until the
display shows
operation.
3) To run through the adjusting range
, use the button
the button
corresponding arrow button to adjust the same
identification number on the transmitter as on the
receiver (the transmitter will only respond to the
REMOSET signal of the receiver with the same
identification number) or select the adjustment
(the transmitter will then respond to the
REMOSET signal of any receiver).
4) Confirm the selection with the button SET.
will be shortly displayed and the unit will go to nor-
mal operation.
5.1.5 Lock function
and then
In the factory, the lock function of the unit has been
deactivated.
When the lock function is activated, the frequency
adjustment via the REMOSET function will not be pos-
sible. Furthermore, it will not be possible to switch off
the transmitter: when the button
display will show
Activating the lock
1) Keep the button SET (6) pressed for approx. 2 sec -
onds until the display shortly shows
the group adjusting mode (group indication , , or
will flash).
2) In the group adjusting mode, press the button SET
five times to go to the adjusting mode for the lock
function. The display will show
Note: To exit the adjusting mode without making an
adjustment, press the button SET. The display will show
and the unit will return to normal operation.
. The unit will then return to normal
(7) for upward selection and
(8) for downward selection. Use the
(4) is pressed, the
(„lock on").
and then
and the
,
...
and then
(„lock off").