Dynamic load management is
disabled
Dynamic load management is
enabled
Dynamic load management is
delaying or limiting the charging
Error
Note! If you have a 3-phase charging station (EVH163B... / EVH323B...) and all phases are connected, the ap-
plication shows the highest charging current and the charged energy is calculated from that value. The actual
total charged energy may be lower than calculated.
14.4. Operation mode
•
The default setting for the charging station is «Free charging».
•
You can change the operating mode to «Authorized» in «Settings/Charger/Operation mode».
•
In the «Authorized» mode you start and stop charging with the application.
14.5. LED brightness
•
The default setting for the LED brightness is 50%.
•
This setting affects the idle power loss: LED 1% => 1,5W / LED 50% => 1,8W / 100% => 3,9W
14.6. Maximum charging current
•
The nominal charging current depends on the charging station model.
•
If your installer has set the maximum charging current to a lower value, it is due to restrictions on the
installation site.
•
You can charge your vehicle at a lower current than the set maximum value. Notice that in that case it
takes longer to charge your vehicle fully.
You can set the charging current from the home screen or «Settings/ Charger/ Max. charging current».
•
14.7. Property energy meter
You can enable / disable the external meter from «Settings/Load Management/Property energy meter».
14.8. External control
You can enable / disable the override mode from «Settings/Load Management/External control (Dry con-
tact)».
14.9. Error messages
At error state, an error code appears on the screen of your mobile device. If you need to contact Ensto Chago
related to faulty operation of the charging station, go first to «Settings/Charger/Error log». Save the error log
information before contacting. This information helps the technical support and maintenance to resolve the
issue.
Note! In some situations the charging station automatically returns to normal operation within approximately
5 minutes after disconnecting the charging cable.
Please see the following table for the cause and corrective actions.
8 / 84
RAK135B / 2024-04-22
External control is disabled
External control is enabled
External control is delaying or
limiting the charging
Error