3.
Reinstall the sear burner. Tighten the two screws on the
rear of the sear burner.
4.
Reinstall the ignitor pin.
5.
Open the manual shutoff valve in the gas supply. The
valve is open when the handle is parallel to the gas pipe.
6.
Test all connections using an approved noncorrosive
leak- detection solution. Bubbles will show a leak.
Correct any leak found.
7.
For normal operating sequence of the ignition system,
see "Lighting Instructions" on page 9.
Change the Rotisserie Burner Orifice
1.
Use an adjustable wrench to remove the brass elbow.
2.
Use a 6 mm socket wrench or 6 mm nut driver to remove
the orifice. Replace with the corresponding natural gas
orifice.
IMPORTANT: Check that the NG orifice is properly
installed inside the valve.
3.
Reinstall the rotisserie burner brass elbow by using a
wrench.
4.
Open the manual shutoff valve in the gas supply. The
valve is open when the handle is parallel to the gas pipe.
5.
Test all connections using an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct
any leak found.
14