Correction of Malfunctions
Problem
Problem
Battery charge
indicator (3) lights
up continuously
No charging
possible
Battery charge
indicator (3) does
not light up
Working notes
A significantly reduced operating time after charging indicates that the battery is used
up and needs to be replaced.
The charger can heat up during continuous charging cycles or charging cycles that
follow each other several times without interruption. However, this is harmless and
does not indicate a technical defect of the charger.
Maintenance and cleaning
If replacement of the connecting cable is necessary, then this must be carried out by
If replacement of the connecting cable is necessary, then this must be carried out by
Wagner or a customer service centre authorised by Wagner in order to avoid safety hazards.
Wagner or a customer service centre authorised by Wagner in order to avoid safety hazards.
Environmental protection
Chargers, accessories and packaging should be recycled in an environmentally
friendly manner. Rechargeable batteries/batteries must not be disposed of with
household waste.Do not throw chargers in the household waste! According to
the European Directive 2012/19/EU on waste electrical and electronic equipment
and its implementation in national law, chargers that are no longer usable must
be collected separately and recycled in an environmentally sound manner.
8
Cause
Cause
Battery not (correctly)
attached
Battery contacts dirty
Battery defective
Mains plug of the charger
not (correctly) plugged in
Socket, mains cable or
charger defective
STARTER KIT 18V
Remedy
Remedy
Place the battery correctly on
the charger
Clean battery contacts; e.g.
by plugging and unplugging
the battery several times,
replace battery if necessary
Replace battery
Insert the mains plug
(completely) into the socket
Check the mains voltage, if
necessary have the charger
checked by an authorised
Wagner customer service
centre.