Télécharger Imprimer la page

Black Max BM905000 Manuel D'utilisation page 18

Publicité

To stop the engine in an emergency situation:
 Put the engine switch in the OFF ( O ) position.
WARNING:
While operating and storing, keep at least 3 feet of
clearance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
Only the parts shown on the parts list are intended to be
repaired or replaced by the customer. All other parts should
be replaced at an authorized service center.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
 Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
 Clean air vents with low pressure air that does not exceed
25 psi.
 Wipe the exterior surfaces of the generator with a damp
cloth.
CHECKING/CLEANING AIR FILTER
See Figure 12.
For proper performance and long life, keep air filter clean.
 Release latches on left side of air filter cover. Remove
cover and set aside.
 Remove the filter element.
 If the filter element is dirty, clean with warm, soapy water.
Rinse and let dry.
OPERATION
HIGH ALTITUDE OPERATION
Specific modifications are needed for high-altitude operation.
Please contact your authorized service center for important
information regarding these modifications. Operating this
engine without the proper altitude modification may increase
the engine's emissions and decrease fuel economy and
performance.
MAINTENANCE
 Apply a light coat of engine lubricant to the element, then
squeeze it out.
 Replace the element in the air filter unit.
 Replace the air filter cover and latch to secure.
NOTE: Do not run the generator without the air filter. Rapid
engine wear will result.
CHANGING ENGINE LUBRICANT
See Figure 13.
 Remove the lubricant cap/dipstick.
 Place a container underneath the lubricant drain plug to
collect used lubricant as it drains.
 Unscrew the lubricant drain plug and remove.
 Allow lubricant to drain completely.
 Reinstall the lubricant drain plug and tighten securely.
 Refill with lubricant following the instructions in the
Checking/Adding Lubricant
 Reinstall the lubricant cap/dipstick.
NOTE: Used lubricant should be disposed of at an ap-
proved disposal site. See your local lubricant retailer for
more information.
SPARK PLUG MAINTENANCE
See Figure 14.
The spark plug must be properly gapped and free of deposits
in order to ensure proper engine operation. To check:
 Remove the spark plug cap.
 Clean any dirt from around base of spark plug.
 Remove spark plug using wrench (not included).
 Inspect spark plug for damage, and clean with a wire
brush before reinstalling. If insulator is cracked or chipped,
spark plug should be replaced.
Page 14 — English
section..

Publicité

loading