Change the battery protection function
1.
Press
until ,
2.
Stop pressing to confirm the new setting.
Change the cooling capacity
CAUTION
The device has an ECO mode that uses 20% less power. Use the ECO mode if
you are using the device in a vehicle or on a vessel. The device takes longer to
reach the desired temperature in ECO mode.
1.
Press
until MAX or ECO flashes.
2.
Stop pressing to confirm the new setting.
Switching off
1.
Press
for 5 seconds.
USB port (5 V, 1 A)
When the device has power, other devices (like a mobile phone) can be charged through the
USB port.
Battery protection function
CAUTION
When the vehicle or vessel engine needs to be started, we recommend setting
the battery protection to high.
CAUTION
The device is measuring the voltage input of the device, not the voltage of the
vehicle or vessel battery.
CAUTION
When the battery voltage protection function shuts down the device error
code 'Er1' will appear on the display.
The battery protection function prevents draining the battery of the vehicle or vessel.
Battery voltage
protection
High
Med
Low
28
or
flashes.
12 V stop
11,7±0.3 V
10.7±0.3 V
10.2±0.3 V
12 V start
12,7±0.3 V
11,7±0.3 V
11,2±0.3 V
24 V stop
24.6±0.3 V
22.6±0.3 V
21.6±0.3 V
24 V start
26.0±0.3 V
24.0±0.3 V
23.0±0.3 V