EN
CARE
• Use a soft, dry cloth.
• For persistent stains, use a cloth dampened with soapy water and wipe immediately with a dry cloth.
TROUBLESHOOTING
Malfunctions are often due to minor causes; please read the table below before contacting the after-sales ser-
vice. This can save you time and avoid unnecessary expenses.
Problem
The device does not turn
on.
The unit does not heat.
The remote control does
not work
The display indicates "EE"
and beeps for 5S
The display indicates "88".
Replacement of the remote control batteries.
1 - Press gently on the cover of the
battery compartment and push
it in the direction of the arrow in
order to remove it.
The lightboard is not replaceable
Causes, Solutions
Check that the device is electrically powered.
Check the temperature of the room: if it is too high compare to the setpoint temperature, the
unit does not heat.
Check the batteries.
Orient the remote control towards the device at a distance less than 1.2 m.
A short circuit has been detected, consult the after-sales service
Thermal security has been triggered. Disconnect the device, eliminate the cause of
overheating, and let cool for 15 minutes before using again.
2 - Insert 2 AAA (R03) 1.5 V batteries
into the compartment.
3 - Make sure you observe the
126
right polarity ("+" and "-").