You can solve many common problems easily, saving you the cost of a possible service call. Try the suggestions below to see if you can solve the
problem before calling the service centre.
Problem
The heater does not operate,even
when it is plugged in and the
switch, thermostat are switched on
The heating element glowing
The appliance didn't heat up, or
only ventilator worked
Abnormal noise
Disposal
Waste electrical production should not be disposed of with household waste. Please recycle where facilities exist. Check with your
Local Authority or retailer for recycling advice.
Environmental Protection
Model identifier(s): 90-065
Item
Symbol
Heat output
Nominal heat output
Pnom
Minimum heat output
Pmin
(indicative)
Maximum
Pmax
continuous heat
output
Auxiliary electricity consumption
At nominal heat
elmax
output
At minimum heat
elmin
output
In standby mode
elSB
Contact details:
Grupa Topex Sp. z o. o. Sp. k. Ul. Pograniczna 2/4, 02-285 Warszawa
Remark:
For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot be worse than the declared value at
the nominal heat output of the unit.
Model identifier(s): 90-066
Item
Symbol
Heat output
Nominal heat output
Pnom
Minimum heat
Pmin
output (indicative)
Possible cause
The plug is loose, bad connection
No power in socket outlet
The input voltage is too high or too low
The air inlet grill is blocked
The switch was not put at heating setting
The thermostat operated
The self-resetting cut-out operated
The appliance is not stands upright
Value
Unit
Item
Type of heat input, for electric storage local space heaters only (select one)
2
kW
Manual heat charge control with integrated thermostat
kW
Manual heat charge control with room and/or outdoor temperature
feedback
2
kW
Electronic heat charge control with room and/or outdoor
temperature feedback
Fan assisted heat output
N/A
kW
Type of heat output/room temperature control (select one)
Single stage heat output and no room temperature control
N/A
kW
N/A
W
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
Electronic room temperature control plus day timer
Electronic room temperature control plus week timer
Other control options (multiple selections possible)
Room temperature control, with presence detection
Room temperature control, with open window detection
With distance control option
With adaptive start control
With working time limitation
With black bulb sensor
Value
Unit
Item
Type of heat input, for electric storage local space heaters only (select one)
3
kW
Manual heat charge control with integrated thermostat
Manual heat charge control with room and/or outdoor temperature
1.
kW
feedback
5
Treatment
Pull out the plug, check the connection of the plug
and socket. Then connect again.
Insert the plug in a proper socket
Use power supply according to the rating on the
label
Keep the heater far way from articles like curtain,
plastic bag, paper and other things which can
cover the inlet or can be easily cover on the air
inlet
Turn the switch to heat setting
Turn the thermostat and listen if there is
open/close voice. If there is no click and the
thermostat is not damaged, the heater will
automatic switch on when the appliance cooled
down
Turn the heater off and inspect the blockage of
inlet or outlet. Disconnect the plug and wait at
least 10 minutes for the protection system to
reset before attempting to restart the heater.
Put the heater on a level surface