PCE IR 50 Série Guide De L'opérateur page 2

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PCE-IR 50 non-contact infrared sensors measure temperatures from -20°C to 500°C and provide
either a linear 4 to 20 mA output, a voltage output or a thermocouple output. This range of output
signals is compatible with almost any indicator, controller, recorder, data logger etc., without the
need for special interfacing or signal conditioning. They are suitable for most materials such as
food, paper, textiles, plastics, leather, tobacco, pharmaceuticals, chemicals, rubber, coal and
asphalt; but not materials with a low emissivity, for example polished metals.
PCE-IR 50 sensors are available as either two-wire or four-wire units.
Two-wire P C E - I R 5 0 sensors transmit the target temperature as a 4-20 mA output and o er a
simple solution for most non-contact temperature measurement applications.
Four-wire P C E - I R 5 0 sensors transmit the target temperature as a 0-50 mV or thermocouple
output (type J, K or T) plus the internal sensor temperature as a 4-20 mA output. This second
output can be used to ensure that the sensor is being operated within the correct ambient tem
perature limits and prevent damage caused by overheating or overcooling. It can also be used to
give an approximate indication of the air temperature surrounding the sensor.
SPECIFICATION
Temperature Range vs Field-of-View table
Field of View
15:1
Output table
Model-X
-0
-1
-2
-3
-4
GENERAL
Accuracy
Repeatability
Emissivity
Response Time
Spectral Response
Supply Voltage
Sensor Voltage
Maximum Loop Impedance
Output Impedance
MECHANICAL
Construction
Dimensions
Cable Length
Weight with 1 m Cable
E NVIRON MENTAL
Environmental Rating
Ambient Temperature Range
Relative Humidity
2
-20ºC to 100ºC
PCE-IR 50 LT-X
Target Temperature Output
4-20 mA
0-50 mV
Type T thermocouple
Type J thermocouple
Type K thermocouple
±1% of reading or ±1°C whichever is greater
±0.5% of reading or ±0.5°C whichever is greater
0.95 ( xed)
240 ms (90% response)
8 to 14 µm
24 V DC (28 V DC max.)
6 V DC min.
900 ohms (4-20 mA output)
56 ohms (voltage/thermocouple output)
Stainless Steel
18 mm diameter x 103 mm
1 m as standard (up to 30 m available on request)
95 g
IP65
0°C to 70°C
95% maximum non-condensing
0ºC to 250ºC
0ºC to 500ºC
PCE-IR 50 MT-X
PCE-IR 50 HT-X
Sensor Temperature Output
Not available
4-20 mA
4-20 mA
4-20 mA
4-20 mA
-