Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet.
This dryer must not be installed behind a lockable door,
a sliding door, or a door with a hinge on the opposite side
to that on the dryer.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease of
installation, servicing, and compliance with local codes and
ordinances.
If installed in a closet with a door, the minimum unobstructed air
opening in the top and bottom is required. Louvered doors with
equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation Clearances
381 mm
(15")*
0 mm (0")
Recessed front view
Additional clearances for wall, door, and floor moldings may be required or if
external exhaust elbow is used.
310 cm
2
(48 in
2
.)*
Front
closet
View
door
155 cm
2
(24 in
2
.)*
356 mm
(14") max.
Closet
door
0 mm
(0")
0 mm (0")
25 mm (1")
Closet side view
76 mm (3")
*Opening is the minimum for a
closet door. Louvered doors with
equivalent air openings are
acceptable.
76 mm (3")
Product Dimensions 686 mm (27") dryer
686 mm (27")
ELECTRIC
BACK VIEW
330 mm
152 mm
(13")
(6
3
⁄
")
4
GAS
32 mm
(1
1
⁄
")
4
743 mm (29
673 mm (26
SIDE VIEW
889 mm
(35")
25 mm
(1")
356 mm
(14")
940 mm
(37")
102 mm (4")
121 mm
dia.
(4
3
⁄
")
4
EXHAUST
1
/
")
4
1
/
")
2
200 mm (7
7
⁄
")
8