Comunication
2.
to find the devices and also allows to visualise the number of
connected and communicating Solar Inverters.
Export Power
Control: This window allows you to configure
3.
multiple parameters of the Export Power Control system.
Auto
Mode: Enabling this work mode allows the Active
a.
Power Imported/Exported from the Grid to be controlled
by adjusting the parameter with tenths of a percentage
(-1000 to 1000), where -1000 is equivalent to -100.0% of
Energy Imported from the Grid and 1000 is equivalent to
100.0% of Energy Exported to the Grid. In the case of a
three-phase system, it allows different phases to be moni-
tored:
To access the calibration parameters of the current
transformers, a password is required: 'pass-
word123'.
USER MANUAL
bus: Allows to scan the communication bus
MIN: Monitoring of the Low Consumption Phase.
AVG: Monitoring of the Average Consumption of all
Phases.
MAX: Follow-up of the Phase with the Highest Con-
sumption.
The following configuration allows compli-
ance with RD 244/2019 Annex I ITC-BT-40 and
UNE 217001:2020 Tests for systems that prevent the
discharge of energy into the distribution network:
Imported/Exported Active Power
-100.
Control
Phase:
MIN.
Up to a maximum of 30 teams working in parallel.
Percentage of export
b.
ting the export power percentage for all EQX2 Solar In-
verter models (the Solar Inverter is responsible for limiting
the generation).
Safety
Parameters: Allows you to configure the security pa-
4.
rameters of the equipment.
Percentage:
power: If enabled, it allows set-
SLC ENERGY MANAGER ENERGY METER