For the Installer
GENERAL
UKV 40 has several different areas of use.
UKV 40 can be used during external control of the heating
system. The heat pump then charges UKV 40 with floating
or fixed condensing. The external control function controls
the heat distribution from UKV 40 to the consumer.
If the flow to the heating system can be restricted using
radiator thermostats, for example, install a UKV 40 as an
intermediate tank. This ensures a secure flow for the heat
pump.
UKV 40 also allows a greater flow to the heating system
than across the heat pump.
In some installations, so-called heating clicks occur as a
result of movements during changes in temperature. To
eliminate temporary changes in temperature, and thereby
prevent heating clicks, install a UKV 40 after the heating
installation.
UKV 40 can also be used to increase the system volume and
thereby prevent malfunctions.
The accumulator tank consists of a condensation-insulated
steel vessel with polyurethane insulation. Outer cladding in
white, powder-coated sheet metal with ends of durable
plastic.
The accumulator tank is designed and manufactured for a
maximum cut-off pressure of 6 bar.
The working temperature is +4 to +95 °C.
TRANSPORT
UKV 40 should be transported and stored in the dry.
ASSEMBLY
The accumulator tank must be installed in a dry area at a
temperature that does not drop below 0 °C (frost-free).
MOUNTING
UKV 40 has to be installed vertically suspended on the wall.
First install the enclosed mounting bracket on the wall, then
suspend UKV 40 from the bracket.
SUPPLIED COMPONENTS
Suspension bracket.
UKV 40 | EN
COMPONENT LOCATION
UKV 40
PZ3
UL2
Designa-
Name
tion
UL2
Holes for wall bracket
PZ3
Serial number plate
13