Personal Protective Equipment; Before Use; Operation - Hilti TE106 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

(tripping current). Use of a ground fault circuit
interrupter reduces the risk of electric shock.
e) Use of a ground fault circuit interrupter (GFCI)
with a maximum tripping current of 30 mA is
recommended.
5.2.4 Work area safety
a) Ensure that the workplace is well lit.
b) Ensure that the workplace is well ventilated.
Exposure to dust at a poorly ventilated workplace
may result in damage to the health.

6. Before use

7. Operation

DANGER
Always hold the power tool securely with both hands
on the grips provided. Keep the grips dry, clean
and free from oil and grease.
CAUTION
Use clamps or a vice to hold the workpiece securely.
7.1 Preparation
7.1.1 Fitting the insert tool 2
CAUTION
Wear protective gloves when changing insert tools
as the insert tools get hot through use and they may
have sharp edges.
1. Disconnect the supply cord plug from the power
outlet.
2. Check that the connection end of the insert tool is
clean and lightly greased. Clean it and grease it if
necessary.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070791 / 000 / 00

5.2.5 Personal protective equipment

a) The user and any other persons in the vicinity
must wear suitable eye protection, a hard hat,
ear protection, protective gloves and breathing
protection while the power tool is in use.
6.1 Use of extension cords and generators or
transformers
Please refer to section 2 "Description".
3. Push the insert tool into the chuck and rotate it
while applying slight pressure until it engages in
the guide grooves.
4. Push the insert tool further into the chuck until it
is heard to engage.
5. Check that the insert tool has engaged correctly
by pulling on it.
7.1.2 Removing the insert tool 3
CAUTION
Wear protective gloves when changing insert tools
as the insert tools get hot through use and they may
have sharp edges.
1. Disconnect the supply cord plug from the power
outlet.
2. Open the chuck by pulling back the insert tool
locking sleeve.
3. Pull the insert tool out of the chuck.
7.1.3 Removing the chuck 4
CAUTION
Wear protective gloves when changing the chuck.