WARNING:
Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect consumer safety.
It is for this reason that a professionally qualified person should undertake the task who will carry it out in accordance with the technical
regulations in force.
In the event that this advice is ignored and the installation is carried out by an unqualified person, the manufacturer declines all respon-
sibility for any technical failure of the product whether or not it results in damage to goods or injury to individuals.
In case of installation of the cooker on a base, measures have to be taken to prevent the appliance slipping from the base itself
1.1
SUITABLE LOCATION
- This appliance must be installed in accordance with the regulations in force and only used in a well
ventilated space. Read the instructions before installing or using this appliance.
- A gas-powered cooking appliance produces heat and humidity in the area in which it is installed. For this
reason you should ensure good ventilation either by keeping all natural air passages open or by installing an
extractor hood with an exhaust flue. Intensive and prolonged use of the appliance may require extra
ventilation, such as the opening of a window or an increase in speed of the electric fan, if you have one.
- If a hood can not be installed, an electric fan should be fitted to an outside wall or window to ensure that
there is adequate ventilation. The electric fan should be able to carry out a complete change of air in the
kitchen 3-5 times every hour. The installer should follow the relevant national standards.
- Check the compatibility between the Trio and the gas installation. The rating plate on the hob shows the type
of gas with which it is designed to be used. Connection to the mains gas supply or gas cylinder should be
carried out after having checked that it is regulated for the type of gas with which it will be supplied. If it is not
correctly regulated see the instructions in the following paragraphs to change gas setting.
The Trio is factory set for use with the gas type as stated on the packaging and repeated on the rating plate affixed to the cooker.
Natural gas G 20-20 mbar / G 25-25 mbar : main gas
- If necessary, change the gas.
To adapt the gas burners cooker fit suitable jets that provide the nominal flow rate (as explained on paragraph changing the gas type).
• For installation the technician must :
All work must be carried out with the electricity supply disconnected.
The Trio is Class2 - Sub class 1 ; furniture adjacent to the unit must not be higher than the top of the appliance.
- If the Trio is fitted next to a cabinet on either side, the distance between the Trio and the cabinet must be at least 15 cm (see Figure
1); while the distance between the Trio and the rear wall must be at least 5,5 cm. The distance between the Trio and any other unit or
appliance above it (e.g. An extractor hood) must be no less than 70 cm (Figure 1).
-
The cooker has adjustable feet for perfect levelling on the floor.
-
Make the gas connection to the installation according to the gas supply.
-
Connect the cooker electrically in compliance with the information given on paragraph electrcal connection.
- If the gas type has been changed, adjust the minimum flow of each gas burner (as explained on paragraph changing the gas type).
- Connect the Trio to the water supply and the water drainage (see paragraph water connection).
ANY MODIFICATION MADE TO THE GAS SETTING SHOULD BE NOTED ON THE RATING PLATE AFFIXED TO THE COOKER.
This must be done in compliance with the regulations in force in the installation country (For U.K. only: by law the gas installation
\commissioning must be carried out by a "Gas Safe" installer). In all cases, on the gas feed pipe provide a stopcock, a regulator or
regulator release device for propane gas. Only use valves, regulators ends and flexible tubes, regulators with the official mark of
the installation country.
Gas connection according to installation :
Natural Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
Butane Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
Propane Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
1 - provided the flexible hose can be inspected for its entire length.
2 - provided the soft rubber tube can be inspected for its entire length, its length does not exceed 1.5 metres and it is fitted with suitable
clamps at the ends.
1, 2 - soft tubes and flexible hoses with mechancial fittings must be arrange to be away from any flames, and not deteriorated by the
combustion gases, hot cooker parts or by any spills of hot food.
The flexible tube shall be fitted in such a way that does not pass through any space where it may become crushed/ kinked or damaged
in any way.
INSTALLATION
GAS MODEL
07 GB
Figure 1