OPERATING AND MAINTENANCE MANUAL
PYD SERIES SOLAR INVERTER
A1-25 = Underconsumption alarm. This parameter is variable depending on the characteristics of the
well. To determine the value we will use the potentiometer turning it to the left until it stops drawing
water, at that point we will look at the upper display that will indicate the consumption of the motor when
it is not able to draw water. Enter this value in the A1-25.
7. ALARM CODES
Code
A-LP
Low voltage rest
A-LS
Underfrequency sleep
Protection against
A-LL1
underconsumption
A-TF
Full protection
Protection against lack of
A-LL
water
www.proindecsa.com / proindecsa@proindecsa.com
Name
If the value is lower than A1-09, the low voltage alarm shall be
activated.
If the conditions of A1-22/23 are met, the light standby alarm will
be activated.
If the conditions of A1-25/26 are met, the underload protection
alarm will be activated.
Set the DI terminal to 52, enable ON.
Set DI terminal to 53, enable ON
Description