Télécharger Imprimer la page

Continental CDVS500-1NEA Manuel D'installation Et D'opération page 35

Publicité

Les langues disponibles

Les langues disponibles

9.1
check pressure readings
Inlet pressure can be checked by turning screw (A)
counter-clockwise 2 or 3 turns and then placing pressure
gauge tubing over the test point. Gauge should read as
described on the chart below. Check pressure with main
burner operating on "HI".
Outlet pressure can be checked the same as above
using screw (B). Gauge should read as described on the
chart below. Check pressure with main burner operating
on "HI".
After taking pressure readings, be sure to
turn screws clockwise firmly to reseal. Do not
overtorque.
Leak test with a soap and water solution.
Pressure
Natural Gas
(inches)
Inlet
(minimum 4.5")
Outlet
9.2
venturi adjustment
This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will cause
a more blue flame, but can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 minutes for the final flame
colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER.
note:
It is important that the orifice is securely inserted into the venturi.
FRONT BURNER
NG 1/4" (6.4mm)
P
1/4" (6.4mm)
Natural Gas
(millibars)
*7"
17.4mb
(minimum 11.2mb)
3.5"
8.7mb
REAR BURNER
1/2" (13mm)
1/2" (13mm)
9.0 adjustments
ELECTRODE
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME
SENSOR
TOP VIEW
B
A
SIDE VIEW
PILOT OUTLET
Propane
(inches)
13"
(minimum 11")
10"
VUE DE
B
A
*Maximum inlet pressure not to exceed 13"
DESSUS
VENTURI
VUE DE
CÔTÉ
BURNER
SORTIE DE PILOTE
ORIFICE
33.1
AIR SHUTTERS
FRONT BURNER
adjustments
PILOT
BURNER
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
Propane
(millibars)
32.4mb
(minimum 27.4mb)
24.9mb
AIR
SHUTTER
OPENING
REAR BURNER
W415-4082 / B-0 / 08.27.24
EN
35