Troubleshooting

If the indicator lamp for emptying the urine container is
not working
If the urine container light does not come on when the tank is full, please check the following:
• Is there power in the wall socket?
• Is the battery/power source supplying the toilet with power?
• Are the connections and cables correctly connected to the back of the toilet?
• Is the plug for the sensor under the toilet correctly connected?
If it smells
A urine-diverting toilet from Separett should, thanks to the well-developed urine diverting and
its constant air flow, ensure that the bathroom remains odorless. In the case of odors occurring,
please check the following:
• Is the fan running properly? If the fan is not running properly, make sure that:
1. Power is being supplied by the power source.
2. The fan plug is properly connected.
3. The cables on the back are properly connected.
• Is the ventilation grid on the pipe cap clean?
• Is the insect net of the ventilation outlet clean?
• Has the piping been carried out in accordance with the instructions?
Problems with pests in the toilet
Assuming a correct installation and correct use of Separett Tiny, the toilet space should be odor
free. This means that the toilet does not need to have any additional material (such as sawdust)
added to the waste container*. If you still have problems with pests in the toilet, please check
the following:
• Make sure that the insect net is intact and firmly attached to the ventilation
• Check that the ventilation pipe is intact and that its joints are tight and sealed
*Loose additional material also contributes to blockages in filters and can shorten the lifetime of
the fan