4. Press SELECT again to display the "Recharge
Days" screen.
MAXIMUM DAYS BETWEEN REGENERATIONS:
The electronic controller automatically determines
regeneration fre quency. This provides the greatest
operating efficiency and, under most conditions this
feature will be left in its default mode. However,
you can set this feature to force a regeneration
every set number of days. You may want to do this
if, for exam ple, your water supply contains iron and
you want the softener to regenerate at least once
every few days to keep the resin bed clean. Use
s
the
UP or
DOWN buttons to change the
number of days (up to 15). If no change is desired,
continue to next step.
5. Press SELECT again to display the "12 or 24 hr"
screen.
12 OR 24 HOUR CLOCK: All time displays are
shown in 12 hour (AM/PM) time format at the
default setting. If 24 hour time format is de sired,
set to 24 hr by pressing the
Questions? Call Toll Free 1-800-754-7027
When you call, please be prepared to provide the model and serial number,
Controller Features
FIG. 50
FIG. 51
UP button.
found on the rating decal inside the salt lid.
19
6. Press SELECT again to display the backwash time
"Add" screen.
BACKWASH & FAST RINSE TIMES: If you expe-
rience salty tasting water after regeneration, you
may need to increase the backwash and fast rinse
times. The cycle times during regeneration are
determined by the softener's electronic controller.
However, you may increase the backwash and fast
rinse times, in 1 minute increments.
If you wish to increase the backwash time, use the
s
UP or
DOWN buttons to add up to 15 min-
utes. Then press SELECT to display the fast rinse
time "Add" screen.
If you wish to increase the fast rinse time, use the
s
UP or
DOWN buttons to add up to 15 minutes.
7. Press SELECT to return to the normal run (time of
day) screen.
www.rheemwatertreatment.com
or visit
FIG. 52
FIG. 53
FIG. 54