Do not flambé under the range hood.
CAUTION: Accessible parts may become hot when used with cooking
appliance
Only plug this unit into a properly earthed outlet. If in doubt seek
advice from a suitably qualified engineer.
Failure to follow these instructions can result in death, fire, or
electrical shock.
Electrical Installation
All installation must be carried out by a competent person or qualified
electrician. Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate.
Direct Connection
The appliance must be connected directly to the mains using an
omnipolar circuit breaker with a minimum opening of 3mm between
the contacts.
The installer must ensure that the correct electrical connection has
been made and that it complies with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage. If the
supply cord is damaged, it must be replaced by a special cord or
assembly available from the manufacturer or its service agent.
WARNING: This is a Class I appliance and MUST be earthed
This appliance is supplied with a 3 core mains cable coloured as
follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
32
The fuse must be rated at 3 Amps.
Electrical Shock Hazard
36