immediately and contact your service station:
In the event of unusual vibrations or noise.
If the engine appears to be overloaded or runs
unevenly.
8.1 Changing the oil and checking the oil level
(before using the machine)
time when the engine is warm after approx. 20
hours of service. After this the engine oil must
be changed every 100 hours of service when the
engine is warm.
Use only engine oil (15W40)
surface
Undo the oil drain screw (Fig. 6/Item D) and
drain the warm engine oil through the drain
channel into a container.
After all the oil has drained out, tighten the oil
drain screw and clean the drain channel with a
cloth.
Add engine oil up to the top mark on the oil
dipstick.
Important: Do not screw the dipstick in to
check the oil level, simply insert it up to the
thread.
Dispose of the waste oil properly.
replace it if necessary.
Do not use abrasive cleaning agents or petrol to
clean the elements.
surface.
diesel in tank you prepare a funnel and an empty
diesel canister.
Loosen the metal hoop on the both sides of the
Immediately insert the fuel hose into the diesel
canister through the funnel and observe the
8.4 Draining the tank
To drain the tank, rst proceed as described in
8.3 Changing the diesel lter (Fig. 7) to remove
the lter.
fuel out of the tank through the
funnel and into the diesel canister. (IMPORTANT:
Ensure that the diesel canister is large enough to
hold all the fuel left in the tank!).
After emptying the tank, reassemble in
reverse order.
9. Winter operation
Since the generator is powered by a diesel
engine, special precautions must be taken for
using it in the winter.
Use "winter diesel" to operate the diesel
generator in outdoor temperatures between -3°C
to -10°C. The change to winter diesel takes place