Power factor cos φ:
Power class:
Max. altitude (above mean sea level):
Battery data:
Length:
Width:
Height:
Operating mode S1 (continuous operation)
The machine can be continuously operated with
the quoted power output.
6. Before starting the equipment
Important.
engine oil and diesel fuel before it is started.
Prepare and connect the battery .
Secure the battery (Fig. 5/Item A) in the unit
using the battery mounting kit (Fig. 3/Item 20).
First connect the red cable (+)
and then the black cable (-) to the battery.
Check the diesel fuel level and top it up if
necessary.
ventilation.
Inspect the immediate vicinity of the generator.
Disconnect any electrical equipment which may
already be connected to the generator.
6.1 Electrical safety:
Electric supply cables and connected
equipment must be in perfect condition.
The generator is to be operated only with
with the generator's output voltage.
Never connect the generator to the power
supply (socket-outlet).
1.0
Keep the cable length to the consumer as short
G1
as possible.
1000 m
12V / 30 Ah
6.2 Environmental protection
19,6 cm
13,2 cm
Dispose of soiled maintenance material and
15,9 cm
operating materials at the appropriate collection
point.
Recycle packaging material, metal and plastics.
6.3 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth
connection on the generator (Fig. 2/Item 14) and
the other end to an external earth (for example
an earthing rod).
7. Operation
7.1 Starting the engine
Check whether the mechanical switch (Fig. 6/
Item A) is set to "RUN".
Important!
The power selector switch is set at the factory
and must not be changed.
Set the ON/OFF switch (Fig. 2/Item 18) to the
"ON" position using the key.
Pull the choke and turn the on/o switch
with the key to "Start".
Release the choke after approx. 5 sec.
and the engine starts to run.
When the engine is running, turn the ON/OFF
switch to "ON".
If the engine does not start straight away
(particularly if the tank was previously empty or
the starting procedure by pulling the
decompression cable again.