BTL KKJJ00- _ _ _ _ -C02NL _ _ 0-000S04
Magnetostrictive Linear Position Sensor – Rod Style
9
Technical data
The specifications are typical values for
BTL KKJJ00- _ _ _ _ -C02NL _ _ 0-000S04 at 24 V DC,
room temperature and a measuring length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R or BTL-P-1014-2R position magnet.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Operating pressure
Short-term pressure load
Typ. temperature coefficient
1)
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock as per
EN 60068-2-27
2), 3)
Vibration as per EN 60068-2-6
Protection per IEC 60529 (when
threaded together)
9.2
Detection range/measuring range
Measuring length
Position resolution
Repeat accuracy
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Non-linearity
Detectable velocity
Velocity resolution
www.balluff.com
−40...+85 °C
−40...+100 °C
≤ 90%, non-
condensing
≤ 600 bar
750 bar
(10 × 1 min)
≤ 30 ppm/K
100 g/6 ms
50 g/2 ms
12 g, 10 ...2000
2), 3)
Hz
IP67, IP69K
25...4000 mm
5 µm
≤ ±10 µm
1000 Hz
500 Hz
250 Hz
±50 μm
≤ 10 m/s
0.1 mm/s
9.3
Electrical data
Operating voltage U
b
Current draw (at 24 V DC)
Power consumption
Overvoltage protection
Voltage-proof up to
(GND – Housing)
9.4
Electrical Connection
Short-circuit protection
Protected against polarity
reversal
9.5
Interface
IO-Link version
Transmission rate
Cycle Time
Data format
Error value
Measuring length 500 mm, position magnet in the middle of the
1)
measuring range
Individual specifications as per Balluff standard
2)
3)
Resonant frequencies excluded
18...30 V DC
≤ 50 mA
≤ 1.2 W
U
up to 36 V DC
b
500 V DC
Signal output to GND
and to 30 V DC
U
up to 30 V DC
b
1.1
COM2 (38.4 kBaud),
COM3 (230.4 kBaud)
≥ 1 ms
32 Bit signed
0x7FFFFFFC
english
15