AV30
Frame and Bowl Assembly
2
When installed properly, the basin will be level and flush to the back wall.
For clarity, the pre-mounted soap spout, faucet spout,
dryer hood and air hoses are not shown.
If access through the basin is preferred, the dryer hood cover
must be removed. Refer to Step 4 for removal instructions.
Position the basin
onto the frame. The
A
right vertical frame
support will fit into
the basin notch as
shown.
Use the back
basin flange
as a template
to mark the (2)
mounting hole
locations onto
the wall. After
marking the wall,
install suitable
wall anchors. See
step 1b.
Drain and P-Trap
3
Use ⁵⁄₆₄" hex driver to
D
install screw to drain
cap assembly.
Drain Cap Assembly
(S45-2714)
Assembly o-ring, drain
B
adapter and packing
washer to basin hub
with (4) #10 screws.
Do not overtighten the
screws on the drain adapter!
12
O-Ring
(125-111)
Packing Washer
(142-135)
#10 Screw
P10-225
P-trap
1/21/2014
C
For clarity, the soap spout, faucet spout, dryer
hood and frame are not shown.
Drain Adapter
(111-091)
P-Trap Outlet
C
Attach p-trap to
outlet and drain.
Bradley • 215-1771 Rev. D; ECN 13-08-028
Installation
Secure the basin flange
B
to the back wall using
suitable
" fasteners
³⁄₈
supplied by the installer.
Access the basin
flange from the
underside or through
the dryer hood
access hole. Refer
to page 12 for dryer
hood cover removal
instructions.
Secure the bowl to the
frame with the two ¼"-20
x
" screws (p/n 160-
³⁄₈
389) and washers (p/n
142-002DB) provided.
A
Install p-trap outlet to
stub out from wall.