˜ Assembly
(Fig . E)
m
DANGER!
The square tube (cross sectional
u
dimensions: 45 x 45 mm) must be able
to bear a minimum load of 500 kg at
the points where the product is fastened .
It is recommended to consult qualified
personnel (for example a structural
engineer) for assembly .
Because special knowledge is required,
u
seek advice from a qualified technician to
ensure all screws are tightened fully and
correctly .
A qualified technician or a properly
u
trained person should also check the
anchoring of the square tube before the
product is fastened .
Time needed for assembly: approx . 1 hour
u
Fasten the product with the mounting
¾
brackets 1 and the mounting screws 2 to
a suitable square tube .
Tighten the mounting screws 2 .
¾
˜ Operation
NOTE
The product has been outfitted with a
u
thermostat switch . During operation, it may
stop the motor 3 . The motor can be only
started again once it has cooled down .
20 GB/IE
˜ Winding/unwinding the cable
(Fig . J)
Winding the cable: Press the control
¾
switch 8 upwards according to the arrow
indication .
Unwinding the cable: Press the control switch
¾
8 downwards according to the arrow
indication .
˜ Lifting loads
Lower the steel cable 14 so you can handle
¾
it comfortably .
Fasten the load to the hook 10 12 . Use
¾
additional bungee cords where necessary .
The load's centre of gravity must be beneath
the product .
Wind up the steel cable 14 until it is only
¾
taut . Then fully lift the load .
˜ Maximum/minimum length
levers
NOTE
The maximum/minimum length levers 15
u
16 are not intended to regularly stop
the product . Always attempt to stop the
product before it triggers one of these
levers .
Minimum cable length lever
When the steel cable 14 is fully wound up, the
minimum cable length lever 15 will be triggered .
The steel cable cannot be wound up any further . It
can only be unwound .
Maximum cable length lever
When the steel cable 14 is fully unwound, the
maximum cable length lever 16 will be triggered .
The steel cable cannot be unwound any further . It
can only be wound up .