Open window detection:
This heater is equipped with an open window detection function. If our control
system detects that the room temperature decreases dramatically in short period
when the heater is in the heating status, it will recognize that a window is open.
The window sign on the screen will start to flash and the heater will power off for
30 minutes and get back to the previous setting automatically after 30
minutes.
You can deactivate and activate this function by long pressing for 5 seconds the "-"
button, and the
open window sign on the screen will disappear and appear accordingly.
Temperature calibration
Long press "+" button for 5 seconds to enter the temperature calibration, adjust
the number by pressing "-" or "+" button, the calibration ranges from -5 to +5
degrees.
WIFI reset
Turn on the heater and long press "WIFI" button for 5 seconds until the WIFI
indicator starts to flash to reset the Wifi connection.
WIFI function ON/OFF
Turn on the heater and long press "Timer" button for 10 seconds to deactivate the
WIFI function of this heater and the WIFI sign on the screen will disappear, long
press "Timer" button for 10 seconds to activate it on again.
Manual control
To enter the manual mode, activate the power switch, press power button to
power on the heater.
Adjust your desired temperature by pressing "-" or "+" button, 2 seconds later the
screen will retain to the reading of current room temperature.
If you would like to set up the timer, press timer button and "00H" will appear on
the screen and you can set the timer by press "-" and "+" button to start the count-
down timer.
You can also use the remote controller to operate your heater manually. However,
when using the remote controller, make sure you are pointing the remote
controller to the control box on the back