In the standard version, the transducer is designed for dynamic application up to a
Calibration
vibration bandwidth of "100% F
used up to 200% F
TEDS integration (integrated electronic data sheet) in accordance with IEEE1451.4
Transducer
identification
The sensitivity is determined at the factory with the bolted‐on adapter. The bolted‐on
Mechanical
adapter ensures the best‐possible screw‐fastening conditions and allows the
design
transmission of axial force through a central internal thread. If the adapter is not used, a
sensitivity deviation of t1% must be taken into account.
Mechanical protection through the installation of an additional square profile around the
Plug protection
connector.
Dimensions in mm approx.: WxHxB: 30x30x20
The standard version is the male device connector with bayonet locking
Electrical
(PT02E10-6P‐compatible). The option is also available to install a screw‐fitting male
connection
device connector (PC02E10-6P‐compatible). A third variant where the force
Bridge A
transducers are fitted with a fixed cable is also available. In this version, all U10 achieve
degree of protection IP68 with a nominal (rated) force equal to or greater than 12.5 kN.
The standard version is the male device connector with bayonet locking
Electrical
(PT02E10-6P‐compatible). The option is also available to install a screw‐fitting male
connection
device connector (PC02E10-6P‐compatible). Both these connection variants are often
Bridge B
used for differentiation in the double‐bridge version. A third variant where the force
transducers are fitted with a fixed cable is also available. In this version, all U10 achieve
degree of protection IP68 with a nominal (rated) force equal to or greater than 12.5 kN.
Mounted force application. Standard is without force application, if requested, we can
Force
mount a force application bolt. Dimensions, see Chapter 10.
application
HBM
. For quasistatic applications, the transducer can be
nom
. The option is available to calibrate accordingly to 200% F
nom
U10M, U10S
.
nom
A1385-6.2 en/de/fr