DIMENSION GUIDE
Electrical Requirements - Canada
Only
WARN I N G
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
■ Check with a qualifi ed electrical installer if you are not sure the
range is properly grounded.
Range Rating*
120/240 V
120/208 V
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit.
For 50 A rated cord kits, use kits that specify use with a nominal
1
⁄
" (3.5 cm) diameter connection opening.
3
8
IMPORTANT: Dimensional specifi cations are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Owner's Manual before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
appliances are appropriately UL, CUL or CSA approved.
®
■ When a 4-wire, single phase 240 V, 60 Hz, AC only electrical
■ A time-delay fuse or circuit breaker is recommended.
■ This range is equipped with a UL or CSA International
■ Do not use an extension cord.
■ The wiring diagram is located on the back of the range or in a
Specifi ed Rating
of Power Supply
Cord Kit and
Circuit Protection
Ampere
40 or 50**
50
supply is available, a 40 A minimum circuit protection is
required on 30" (76.2 cm) ranges, fused on both sides of the
line.
Certifi ed Power Cord intended to be plugged into a standard
14-50R wall receptacle. Be sure the wall receptacle is within
reach of range's fi nal location.
clear plastic bag.
5 of 15