12
Warranty
1) DiaDent provides a 1-year free warranty and repair of this device (1 year from the date of purchase) for defects
in performance and accessories when used in compliance with the instructions and precautions in the product
manual. (However, ultrasonic tips and battery packs are consumables and are not covered under warranty.)
2) To obtain warranty coverage, please contact the place of purchase to ship the product to the
manufacturer's service center.
3) Product shipments for product warranty benefits must be securely packaged and the shipping cost
must be prepaid. Manufacturers do not accept products shipped on a postpaid basis. The manufacturer is
responsible for repair and replacement of the product.
4) The warranty is void in the following cases :
- Failure caused by not using the product in the manner described in the user manual
- Failure caused by negligence in handling
- Failure due to natural disaster
- Failure caused by not using the specified power source (Do not use the charging adapter with other products)
- If the product is disassembled and repaired
13
Specifications
Product Name
Model Name
Ultrasonic Frequency
Charging Time
Duty Cycle
Operation Time per Full Charge
Hand-piece
Charger
Dimensions
Ultrasonic Tip
Wrench
Hand-piece
Charger
Weight
Ultrasonic Tip
Wrench
Input
Power Supply
(Adapter)
Output
Battery
Voltage, Capacity
Temperature(
Operating
Ambient Pressure
Conditions
Relative Humidity
Temperature(
Transportation
and Storage
Ambient Pressure
Conditions
Relative Humidity
16
Ultrasonic Endodontic Activator
Dia-Ultrasonic
30KHz ~ 45KHz
Approximately 3 hours 30 minutes
Operation Time : up to 15 seconds
Break Time : at least 5 seconds
For 15 seconds up to 500 times
178 x 25 x 25mm(L x W x H)
91 x 91 x 44mm(L x W x H)
27 x 32 x 4mm(L x W x H)
74 x 12 x 12(L x W x H)
101g
135g
0.8g
15g
100-240V~, 50/60Hz, 0.4A
5V
2A
Li-ion 3.65V
, 2750mAh / Rechargeable
℃
)
10 ~ 30
℃
70 ~ 106 (KPa)
30 ~ 85 %
)
-10 ~ 40
℃
℃
70 ~ 106 (KPa)
30 ~ 85 %
14
Symbols
Symbol
Description
Cautions indicate which, if not
observed, could result in damage
to the user and/or device
CE certificate: Product conformance
with the applicable European Union
Directives
Class II Equipment
Manufacturer
Serial No
See instruction manual
Humidity Limitation
Catalog Number
Caution, hot Surface
Be careful to prevent burns
The Restriction of the use of certain
Hazardous Substances in electrical
and electronic equipment
Refer to accompanying
Documents
Prescription Only
Symbol
Description
Direct current
Authorized EU Representative
Type B Applied Part
Manufacture Date
Subject to electrical/electronic
equipment waste regulations
Sitting Prohibited
Temperature Limitation
Atmospheric Pressure Limitation
Keep Dry
Medical Device
Refer Servicing to Qualified
personal only
17