Product Specifications

Model
0s
00s*
Certified flow rate
8 gpm
9 gpm
@ 15 psi (or less)
30 .3 Lpm
34 . 1 Lpm
Peak flow rate**@
12 gpm
16 .5 gpm
30 psi (or less)
45 .4 Lpm
62 .5 Lpm
Resin per tank,
0 .3
0 .47
in cubic feet
Resin per tank, in liters
8 .5
13 .3
Capacity per cycle,
4693 @ 1 .25
7867 @ 1 .8*
in grains @ salt used per
9802 @ 2 . 7
cycle setting pounds
Capacity per cycle, in
304 @ 0 .57
509 @0 .81*
grams @ salt used per
635 @ 1 .2
cycle setting kilograms
Grains exchanged
3754 @ 1 .25
4371 @ 1 .8*
per pound of salt used
3630 @ 2 . 7
Grains exchanged per
534 @ 0 .57
628 @ 0 .81*
kilograms of salt used
529 @ 1 .2
Max. flow rate to drain
2 .3 gpm
0 .69 gpm
during regenerations
8 . 7 Lpm
2 .6 Lpm
Min./max. operating
103 .4 - 861 .9 kPa
pressure
15 - 125 psi
Min./max. operating
2 - 49°C
temperature
35 - 120°F
Max. working
861 .9 kPa
pressure in psi
125 psi
* Meets California efficiency requirements of 4000 grains exchanged per pound of salt used. Efficiency is only
certified at the low salt dosage and was determined in accordance with NSF/ANSI 44.
** Manufacturer' s tested and verified rate- not certified or verified by NSF or WQA
*** Certification pending
Sodium Information: Systems using sodium chloride for regeneration will add sodium to the water. The
amount of sodium added is proportionate to the amount of hardness removed. People who are on sodium-
restricted diets should consider the added sodium as part of their overall sodium intake.
Inlet Hardness
Sodium Added
171 mg/L (10 gr)
79 mg/L
342 mg/L (20 gr)
149 mg/L
513 mg/L (30 gr)
223 mg/L
1192 mg/L (40 gr)
298 mg/L
Kinetico reverse osmosis systems will remove as much as 98 percent of sodium content in the water. Using
potassium chloride as a regenerant will not add sodium to the water.
1
00s with
00s
00s
Overdrive
00c
00c with
(Europe only)
Overdrive
11 gpm
7 gpm
11 .6 gpm
41 .6 Lpm
26 .5 Lpm
43 .9 Lpm
15 gpm
15 gpm
30 gpm
56 . 7 Lpm
56 . 7 Lpm
113 .5 Lpm
0 .4
0 .4
0 . 7
11 .3
11 .3
19 .8
5222 @ 1 . 0 *
5222 @ 1 . 0 *
12,481 @ 2 . 7 *
15,817 @ 4 . 0
338 @ 0 .45*
338 @ 0 .45*
809 @ 1 .23*
1025 @ 1 .8
5222 @ 1 . 0 *
5222 @ 1 . 0 *
4623 @ 2 . 7 *
3954 @ 4 . 0
751 @ 0 .450*
751 @ 0 .450*
658 @ 1 .23*
569 @ 1 .8
1 .5 gpm
1 .5 gpm
2 .5 gpm
5 . 7 Lpm
5 . 7 Lpm
9 .5 Lpm
00s with
100s
100s with
Overdrive
Overdrive
20 .5 gpm
12 gpm
21 gpm
77 .6 Lpm
45 .4 Lpm
79 .5 Lpm
30 gpm
19 gpm
31 gpm
113 .5 Lpm
71 .9 Lpm
117 .3 Lpm
0 . 7
1 .5
1 .5
19 .8
42 .5
42 .5
12,481 @ 2 . 7 *
25,253 @ 5 .5*
25,253 @ 5 .5*
15,817 @ 4 . 0
41,087 @ 10 . 0 *
41,087 @ 10 . 0 *
809 @ 1 .23*
1636 @ 2 .5*
1636 @ 2 .5*
1025 @ 1 .8
2662 @ 4 .5*
2662 @ 4 .5*
4623 @ 2 . 7 *
4591* @ 5 .5*
4591* @ 5 .5*
3954 @ 4 . 0
4109* @ 10 . 0 *
4109* @ 10 . 0 *
658 @ 1 .29*
654 @ 2 .5*
654 @ 2 .5*
569 @ 1 .8
592 @ 4 .5*
592 @ 4 .5*
2 .5 gpm
3 .3 gpm
3 .3 gpm
9 .5 Lpm
12 .5 Lpm
12 .5 Lpm
1s
00s with
00s
Overdrive
(Europe Only***)
16 .4 gpm
11 gpm
6 gpm
62 . 1 Lpm
41 .6 Lpm
22 . 7 Lpm
22 gpm
15 gpm
15 gpm
83 .2 Lpm
56 . 7 Lpm
56 . 7 Lpm
2 .25
Upper: 0 . 4 Resin
Upper: 0 . 4 Resin
Lower: 0 . 4 Carb
Lower: 0 .4 Carb
63 . 7
Upper: 11 . 3 Resin
Upper: 11 . 3 Resin
Lower: 11 . 3 Carb
Lower: 11 .3 Carb
65,139 @ 15*
4921 @ 1 . 0 *
4921 @ 1 . 0 *
81,845 @ 30
4221 @ 6 .8*
319 @ 0 .45*
319 @ 0 .45*
5303 @ 13 .6
4343* @ 15 . 0 *
4921 @ 1 . 0 *
4921 @ 1 . 0 *
2728 @ 30 . 0
621 @ 6 .8*
709 @ 0 .45*
709 @ 0 .45*
390 @ 13 .6
4 .8 gpm
3 . 0 gpm
3 . 0 gpm
18 .2 Lpm
11 .4 Lpm
11 .4 Lpm
172 .3 - 861 .9 kPa
103 .4 - 861 .9 kPa
25 - 125 psi
15 - 125 psi
Kinetico Water Softeners (MACH 2025s, 2030s, 2040s OD, 2040c OD, 2050s, 2050c, 2060s,
2060s OD, 2100s, 2100s OD, 2175s, 4040s OD and 4060s OD with Macrolite or carbon)
are tested and certified by NSF International and/or the WQA against the requirements
of NSF/ANSI Standard 44 for softener performance and chemical reduction of barium and
radium 226/228. The Kinetico 4060s OD with Macrolite is tested and certified by NSF Inter-
national and/or the WQA against the requirements of NSF/ANSI Standard 42 for Particulate
Reduction Class III. The 4060s OD with carbon is tested against NSF/ANSI Standard 42 for
chlorine reduction. NSF International and/or the WQA certifies our product performance and
reviews our manufacturing facility and procedures to assure product consistency and integrity.
They also assure that our literature accurately reflects our product capabilities.
Certified Continuous Flow Rate as validated by NSF International represents continuous service
flow of water at 15 psi pressure drop and is not an indication of maximum flow rate or unit
limitation. U.S. Patents: 4,336,134; 4,579,242; 4,889,623; 4,972,877; 5,022,994; 5,490,932
These products are not intended to be used for treating water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the system.
00s with
00s with
Overdrive-
Overdrive-
Activated
Macrolite
Carbon
11 gpm
10 gpm
41 .6 Lpm
37 .9 Lpm
15 gpm
15 gpm
56 . 7 Lpm
56 . 7 Lpm
Upper: 0 . 2 5 Carb
Upper: 0 . 2 Macrolite
Lower: 0 . 7 Resin
Lower: 0 . 7 Resin
Upper: 7 . 1 Carb
Upper: 5 . 7 Macrolite
Lower: 19 . 8 Resin
Lower: 19 .8 Resin
13,715 @ 4 . 0
14,883 @ 4 .4
889 @ 1 .8
964 @ 2 . 0
3429 @ 4 . 0
3383 @ 4 .4
494 @ 1 .8
482 @ 2 . 0
3 . 0 gpm
3 . 0 gpm
11 .4 Lpm
11 .4 Lpm
1