USING THE APPLIANCE FOR THE FIRST TIME
1.
Ensure that the pump is properly prepared, then turn on the tap slowly.
2.
Connect the control device to the mains supply. The (POWER) LED for the voltage indicator
will light up.
3.
The pump will start up automatically and within 20-25 seconds, the pressure indicator will
show the pump's maximum pressure. The (ON) LED will light up during operation.
4.
Turn off the tap that was turned on in Point 1. The pump will stop within 7-9 seconds. The
(POWER) LED for the voltage indicator will stay on. Any problem that occurs will be down to
the pump being improperly set up.
TROUBLESHOOTING
Problem
Pump does not stop
Pump does not start
Pump is jammed
Error
in
the
electronic circuit
No
mains
power
supply
Pump pressure is not
high enough
Air in the pump
circuit – the pressure
indicator shows a
lower pressure than
Possible cause
Water pressure greater than
1.21 l/min – check the system,
the tap etc.
The manual start switch (RESET)
is jammed
Short circuit in the circuit board
Incorrect electrical connection
on the circuit board
Water supply not sufficient, the
safety system has activated and
the (FAILURE) LED has lit up
(FAILURE) LED lights up and the
safety system has activated
When starting manually using
the RESET switch, the (ON) LED
lights up, but the pump does
not work
The safety system was activated
and
the
corresponding
(FAULURE) LED lights up
The safety system activates,
stops the pump and the
(FAILURE) LED lights up.
Solution
Check the system, the tap etc.
Keep pressing it; contact your dealer
if the problem persists
Change it
Check the connections in accordance
with figure 3
Check the water supply and re-start
the pump using the RESET switch
Start manually using the RESET switch
Please contact your dealer
Switch the mains supply off, wait for
a few seconds and then switch it on
again. If the pump does not start
immediately, replace the circuit
Check that the mains power supply is
working properly. The (POWER) LED
for the voltage indicator should light
up
Ensure that the pump pressure is 0.8
bar greater than the starting pressure
for the control device
Check the seals of the connections
and the O-rings in the suction pipe
12