INDEX
1. Connections and adjustments p. 6
2. TRANSMITTERS
p. 7 - 9
2.1 Radio codes memorization
2.2 Working time configuration (necessary
if 7/42 channel transmitters are used)
2.3 Radio codes deletion
2.4 Remote memorization of other radio codes
2.5 Remote deletion of a radio code
3. SENSORS
p. 9
3.1 WIND sensor
3.2 RAIN sensor
4. Technical specifications
p. 22
1
Connections and adjustments
LR LA LM
DIP SWITCH P1
15
16
17
MOTOR STOPS. The control unit stops the motors at the point of a mechanical
stop through current absorption. The threshold can be set with DIP1 and
DIP2 (table). Attention! Check that the motor only stops at the mechanical
stops (LM = ON): increase the threshold if the motor stops during operation or
decrease if the motor continues to push against the mechanical stops.
WARNINGS
The product at issue must be installed, commissioned and maintained only by licensed and authorised people, respecting
the laws concerning the automatic covers. All the connections must be rated for a single-phase 230Vac power supply. For the
disconnection from the power line, use an all-pole switch with contacts having a dimension of at least 3,5mm. Arrange all the
necessary safety devices and use only materials complying with the standard of electrical installations. The cable must have a
section properly rated according to the load connected. Before the connection to the power supply make sure that the sensors
and motors are correctly connected. A faulty connection of the motors (polarity inversion) could damage them together with the
connected mechanical elements. Use a 2x1.5mm cable to connect the motor and the control unit for length up to 6m, or 2x2.5mm
cable for longer segments. PRODUCT DISPOSAL: at the end of this product's useful life, it must not be disposed of as domestic
waste, but must be taken to a collection centre for waste electrical and electronic equipment. Hereby Teleco automation s.r.l.
declares that the product complies with the essential requirements and other relevant provisions, established by the Directive
1999/5/EC. The declaration of conformity can be consulted on the web site: www.telecoautomation.com/ce. In the view of a constant
development of their products, the manufacturer reserves the right for changing technical data and features without prior notice.
RN
AN
LED
LED
12
11
7
8 9 10
6
5
4
3
2
M
1
DIP1 DIP2
OFF
OFF
ON
ON
Default
1
MOTOR (CLOSE)
2
MOTOR (OPEN)
3
RAIN SENSOR (YELLOW, GND)
4
RAIN SENSOR (BLUE, SIGNAL)
5
RAIN SENSOR (WHITE,+12V)
6
WIND SENSOR (BLUE)
7
WIND SENSOR (BROWN)
8
INPUTS COMMON
9
CLOSE/STOP INPUT (N.O.)
10
OPEN/STOP INPUT (N.O.)
11
AERIAL RF
12
AERIAL GND
15
230Vac POWER SUPPLY (LIVE)
16
230Vac POWER SUPPLY (NEUTRAL)
(A)
17
GROUND
OFF
1
AN LED WIND SENSOR PULSES
RN LED RAIN SENSOR ACTIVE
ON
2
LA
FLASHING = WIND ALARM
OFF
3
LR
ON = RAIN ALARM
ON
4
LM
LIMIT SWITCH LED
P1
PROGRAMMING BUTTON
6
Only in "TS"
version