PoolDose | pH · ORP · Chlorine
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
Note: Timeout for settings menu - after 120 seconds without action the controller escape itself without saving parameters.
View Parameters
Free Chlorine Measure
Alarms
Lev CL
OFA CL
Temperature or Totalizer
Flowrate measure,
Moreover:
Alarms and messages:
• Circ. Pump OFF
• Flow (Reed OFF)
• WiFi OFF
• Remote standby
deletes all measures
• Flow Delay with time
countdown
Calibration Menu:
Press
(3 seconds) and calibrate probe pH, Chlorine, Temperature, ORP
0000138994
: 2 points, Disable,
: Reference, Disable,
: Proportional, OFF, Timed, On/OFF
: Proportional, OFF, Timed, On/OFF
o Note: The ORP dosing is disabled if
: Proportional, OFF, Timed, On/OFF
•
: pH, Disable
•
: Chlorine, ORP, Disable
o Note: Aux1 and Aux2 relays dose with ON/OFF method
0000 (Note: password disabled, set a value other than: 0000)
(Note: select the measure to reset: pH; Chlorine; ORP)
: displays the electrical signals
display error, when reed off): NO/NC
(
Disables the dosing pumps for the set time (OFF...1:90 minutes)
Disables the dosing pumps for the set time (OFF...1:60 minutes)
•
WiFi network name
•
WiFi password
•
WiFi network IP address.
Note: this menu is available for WiFi product only, it is not present in the PoolDose SPA application
°
rev. 3.0
EN
is different than OFF
pH
measure
Alarms:
Lel pH
OFA CL
ORP
Measure
Alarms:
Lev CL(ORP)
OFA ORP
6