PoolDose | pH · ORP · Chlorine
Set menu
Press
(3 seconds) and adjust set point value and press SET to confirm.
Free Chlorine
measure
pH
measure
Calibration Menu
Press
(3 seconds) and calibrate probe pH, Chlorine, Temperature, ORP.
StandBy system
Press
(5 seconds) the system sets in StandBy mode; all functions are disabled.
Reset OFA Timer
Press
(3 seconds) to reset OFA Alarm or press
Priming pumps
Only while the pump is in "stand-by mode" press down
to run ORP/Chlorine pump, press
PoolDose SPA dosage
The regulation of pH and chlorine in the PoolDose Spa system is managed by keeping the pH regulation prior to
the chlorine dosage to obtain a better regulation. This function is only available on PoolDose SPA products.
To restore the default parameters, follow the steps below:
• Power off the PoolDose unit
• Keep
and
• The unit will display
• Press
or
• Select
and press
Default parameters:
• Language = EN
• Set Point value = 7.4 pH; 700 mV; 1.2 ppm
• Dosing method = Acid
• OFA Time = OFF
• Calibration = Full
• Flow Input = OFF (recirculation pump)
• Dosing type = PROP; ON/OFF Relay Aux1 and Aux2
• IN Freq. = OFF
• Reed = NC (normally closed)
• P.ON (On delay) = OFF
• Flow delay = OFF
0000138994
to run the Aux1 Relay, press
pressed and power on the unit
to select
or
to restore the default parameters.
; Low
(pH)
(Redox); Low (Cl)
rev. 3.0
(5 seconds) to reset OFA Alarm.
to reset flow totalizer,
to run the Aux2 Relay.
EN
Quick setpoint menu
ORP
measure
to run pH pump, press
10