2/. Undo the screws on the valve mount brackets at either end of the valve. / Défaire les vis sur les
supports de montage robinet à chaque extrémité de la vanne
3/. Carefully tilt the valve through the opening and lift out of firebox for accessibility. / Soigneusement
incliner la valve à travers l'ouverture et de sortir de la chambre de combustion pour l'accessibilité.
4/. Replace valve in reverse order from steps 3 through 1. / Remplacer la vanne dans l'ordre inverse
les étapes 3 à 1.
WARNING
AVERTISSEMENT
BE CERTAIN TO CHECK FOR GAS LEAKS AT ALL GAS CONNECTIONS AFTER REINSTALLATION OF VALVE.
IL EST INDISPENSABLE DE VÉRIFIER LES FUITES DE GAZ A TOUS LES CONNEXIONS DE GAZ APRÈS LA
RÉINSTALLATION DE LA VANNE.
4.0 MAINTENANCE
4.1 MAINTENANCE SAFETY
WARNING
AVERTISSEMENT
TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO
30 MINUTES BEFORE SERVICING.
COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT
JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
Service and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a professional service technician. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, etc. It is important that the access
door compartment, burner, and circulating air passageways be kept clean to provide for adequate
combustion and ventilation airflow. Do not substitute materials or use components other than factory
supplied.
4.2 RECOMMENDED SERVICE
1. The venting system should be annually inspected by a qualified agency.
2. Visually check the burner and pilot flames occasionally. Visually inspect height and color of
flames
3. Clean the glass as needed. See section 4.3 for instructions on glass cleaning.
4. Have the appliance inspected annually by a professional service technician.
5. Clean the appliance regularly.
Annual service: An annual service call should take between 1 – 2 hours. Start by disassembling the
unit; take off the door and remove all the embers, burner, and logs. Clean fan with a vacuum to
remove any dust. Vacuum the whole firebox and all the air passages. Clean the burner. After
everything is clean, check all the connections and the chassis ground and reassemble. Clean the
glass.
Page 38 of 53