ELITE ST LINEAR FIREPLACE
20,000 BTU/h
Natural Gas & Propane
Installation and Operating Instructions
MODEL: BLST21
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbour's phone. Follow gas supplier's
instructions
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or gas
supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
PLEASE READ THIS MANUAL BEFORE
INSTALLING OR USING THIS APPLIANCE.
SAVE THIS MANUAL FOR FUTURE
REFERENCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF
BURNS FROM THE HOT VIEWING GLASS IS PROVIDED
WITH THIS APPLIANCE AND SHALL BE INSTALLED.
CLIENT # LC773211
WARNING
any other appliance.
SEE-THROUGH – CLEAN FACE
Page 1 of 53

Publicité

loading

Sommaire des Matières pour Savannah Canyon 35

  • Page 1 ELITE ST LINEAR FIREPLACE 20,000 BTU/h Natural Gas & Propane Installation and Operating Instructions MODEL: BLST21 CLIENT # LC773211 SEE-THROUGH – CLEAN FACE WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 ELITE ST FOYER LINEAR 20,000 BTU/h GAZ NATUREL ET PROPANE Manuel D’installation et Guide de l’utilisateur MODEL: BLST21 CLIENT # LC773211 AVERTISSEMENT ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU D'EXPLOSION OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
  • Page 3 Table of Contents IMPORTANT SAFETY INFORMATION …………………………………………………………….. 4 – 5 INTRODUCTION ........................Specifications, Appliance Dimensions & Installation Codes ......... 6 - 7 Features, Remote Control Functions ..............8 - 10 Intended Use ......................11 General Safety ....................11 - 12 OPERATION ...........................
  • Page 4 WARNING  Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Follow instructions for proper installation  Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 5 WARNING AVERTISSEMENT Do not use this appliance if any part has Ne pas utiliser cet appareil s’il a été plongé, been under water. Immediately call a meme partiellement, dans l’eau. Appeler un qualified service technician to inspect the technician qualifié pour inspecter l’appareil et appliance and to replace any part of the remplacer toute partie du système de control system and any gas control which...
  • Page 6 1.0 INTRODUCTION 1.1 SPECIFICATIONS TABLE 1 ITEM NATURAL GAS (NG) PROPANE (LP) INPUT: Hi 20,000 Btu/hr (5.861 kW) 19,500 Btu/hr (5.71 kW) INPUT: Lo 13,000 Btu/hr (3.81 kW) 13,500 (3.96 kW) MANIFOLD PRESSURE: Hi 3.5” w.c. (0.87 kPa) 10.0” w.c. (2.49 kPa) COLLECTEUR DE PRESSION: FORT MANIFOLD PRESSURE: Lo COLLECTEUR DE PRESSION:...
  • Page 7 APPLIANCE DIMENSIONS Figure 1 INSTALLATION CODES This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe. Installation must conform to local codes. In the absence of local codes, installation must conform to the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane Installation Code CSA B149.1.
  • Page 8 1.2 FEATURES Ignition system: Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter. Fan control * Optional * Variable speed control: For units equipped with a fan control, the knob controls the fan speed, turning the knob counter-clockwise turns it to the “Off”...
  • Page 9 Program Mode The Program function is controlled by the PROG/TIME button. The control may be programmed for up to two settings for weekdays and two settings for weekends. The control is preset to factory settings. When the Program Mode is activated, the unit will automatically be operating in the Thermostat Mode. The unit will turn on or off based upon room and set temperature.
  • Page 10 Fan Control The unit must be ON to operate the Fan. The Fan will turn on after 5 minutes of operation. Once the Fan comes on, it can be controlled using the FAN button. Press the FAN button, and the fan icon and speed will appear on the LCD screen. Press the UP or DOWN button to control the fan speed (0-6).
  • Page 11 1.3 INTENDED USE / USAGE PROPOSÉ This appliance is intended to be used as a zero clearance fireplace. This unit is certified for installation in a bedroom, a bed sitting room or a bathroom where the maximum input is within 50 cubic feet per 1000 Btu/hr. In Canada all bedroom installations require the use of wall thermostats (note: thermostats are not allowed in the United States).
  • Page 12 IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. It is not unusual for gas fireplaces to give off some odors the first time they are burned. This is due to the oils and sealants in the manufacturing process.
  • Page 13 2.0 OPERATION LIGHTING INSTRUCTIONS - for Intermittent Pilot FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. BEFORE LIGHTING smell all around the appliance area for gas.
  • Page 14 Pilote intermittent POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT: Quiconque ne respecte pas à la letter les instructions dans la présente notice risqué de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. Cet appareil est équipé d'un dispositif d'allumage qui allume automatiquement le pilote. Ne pas tenter d'allumer le pilote à la main. Avant d’allumer la veilleuse, reniflez tout autour de l’appareil pour déceleur une odeur de gaz.
  • Page 15 2.2 HEAT OUTPUT ADJUSTMENT The valve supplied with the appliance has a HI/LO knob to control the heat output and flame height (see valve diagram in Lighting Instructions, section 2.1). 2.3 FAN OPERATION (optional) For units equipped with a fan control knob, the knob is located in the valve control compartment and may be adjusted to the following settings: OFF: Turn the control fully counter-clockwise until the switch operates.
  • Page 16 3.0 INSTALLATION 3.1 INSTALLATION & SAFETY NOTES / NOTES D'INSTALLATION ET DE SECURITE Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety. Failure to follow these instructions will void your warranty and may present a fire hazard.
  • Page 17 3.3.1 INSTALLING NON-COMBUSTIBLE BOARD WARNING THE SURFACE ABOVE THE APPLIANCE GETS VERY HOT. IF PROPER FINISHING MATERIALS ARE NOT USED, CRACKING CAN OCCUR. LA SURFACE AU-DESSUS DE L'APPAREIL EST TRÈS CHAUDE. SI DES MATERIAUX DE FINITION CORRESPONDANTS NE SONT PAS UTILISES, DES RISQUES PEUVENT SURVENIR.
  • Page 18 3.3.2: MINIMUM CLEARANCES / DÉGAGEMENTS 36.00 Non-combustible board. 11” x 35-3/8” 12.00 32.00 Framing Dimensions 32” (813mm) High x 39-1/2” (1003mm) Wide x 10-7/8” (276mm) Deep Non-combustible Board 11” x 35-3/8” will be supplied by manufacturer MINIMUM CLEARANCES TO COMBUSTIBLES 40”...
  • Page 19 40.000” Clearances are in accordance with local installation codes and the requirements of the gas supplier. **The mantel placement chart on this page illustrates the allowable mantel sizes and placements. The 45 degree angle can be used to determine the allowable mantel size based on the elevation above the units upper trim.
  • Page 20 3.3.3 GAS LINE INSTALLATION / INSTALLATION DE LA LIGNE de GAZ Install supply line using any piping approved for your installation meeting CAN/CGA 6.10, AA 3, ANSI Z21.24 or  Z21.45. A qualified gas fitter should install the gas line in accordance with all local building codes. If codes permit, coiled copper tubing may be used for gas supply.
  • Page 21 The thermostat, digital on/off remote or wall switch MUST be rated for millivolt use. Minimize splicing in all millivolt wiring & crimp all unavoidable splices. Le thermostat numérique, télécommande marche / arrêt ou l'interrupteur mural doit être évalué pour une utilisation en millivolts. Minimiser épissage dans l'ensemble du câblage millivolt &...
  • Page 22 Figure 4 3.3.5 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION The unit must be connected to listed 2-ply aluminium venting and vent cap / termination kit, 4” flex vent on the exhaust side and listed 7” flex vent on the air intake side or can be used with Security Venting, Dura-Vent 4”...
  • Page 23 This appliance’s venting system is room sealed or Direct Vent. This means that it does not require room air for combustion but draws air from outside the building. USE OF COUPLERS – WITH FLEX PIPE In the event of a puncture of the vent pipe or if an extension is needed couplers may be used. High temperature sealant shall be applied to the ends of the coupler and the coupler shall then be inserted into the flex vent.
  • Page 24 The maximum vertical system consists of: ICC adapter TM-A446 directly on top of unit Up to 34' (10363 mm) of vertical length Fire stop Flashing Collar Termination cap part # TM-4VT Security Venting The minimum vent system for horizontal termination must consist of: Dura-Vent adapter Part # W175-0053 directly on top of unit 12"...
  • Page 25 2-Ply Aluminum Flex Vent The minimum vent system for horizontal termination must consist of: 12” (305 mm) horizontal length (measured from center of vent pipe) Wall thimble part# IMC1082A Horizontal termination cap part # IMC1070A or IMC1070B The maximum horizontal vent system consists of: 34’...
  • Page 26 Horizontal/Vertical Venting Sample Chart H Max V + V1 Min H + H1 Max Vertical Venting Sample Chart V + V1 Min H + H1 Max Maximum vertical length 34’(10363mm) Maximum total Horizontal offset 20’(6096mm) USE OF SEALANT Sealant is required on vent system joints, except Metal-Fab Sure-Seal direct vent system joints (figure 7).
  • Page 27 VENT RESTRICTOR INSTALLATION Vent Configuration Restrictor Size Factory set Remove 1 side VENT RESTRICTOR Remove 2 sides To fasten the Restrictor Plate to the ceiling of the firebox: 1/. Remove the 2 screws that are in place 2/. Remove portion of restrictor for your correct air flow 3/.
  • Page 28 12.50” 9.50” ø 13.25” 9” 10.25” ø 7” Safety Cage Mark a 9.5” x 10.25” box around the center mark (inside dimensions). Cut and frame the exterior wall to accept the wall thimble. Install the wall thimble, on the inside of the exterior wall, shield using wood screws. Attach the venting to the termination using sheet metal screws, for Z-Flex installations an Inca Metal Cutting’s termination part # IMC1070A or IMC1070B shall be used and when using Dura-Vent or Security Venting a Dura-Vent termination part # P574 shall be used.
  • Page 29 Vertical Installations Always maintain a 1” clearance around the vent pipe (vertical) and 1” clearance horizontal, when passing through ceilings, walls, roofs, enclosures, attic rafter or any combustible surfaces. DO NOT PACK AIR SPACES WITH INSULATION NE PAS PACK ESPACES D'AIR AVEC ISOLATION When passing through a flat ceiling install a Box/Wall thimble.
  • Page 30 Termination above Roof Consult local codes for minimum vent cap height above the roof (X), vent must be a minimum of 2’ from any wall. To prevent water seepage; install the flashing with upper portion under the roofing material and the lower portion over the roofing material.
  • Page 31 In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code A vent shall not terminate directly above a † sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings Permitted only if veranda, porch, deck or...
  • Page 32 3.3.6 Glass Installation / Installation de verre Burn medium positions are critical to the safe and clean operation of this appliance. Never add any other material into the firebox. Use only with burn medium supplied with this unit. Burn positions moyennes sont critiques pour le fonctionnement sûr et propre de cet appareil.
  • Page 33 Removal is in reverse order. / L'enlèvement est dans l'ordre inverse. If the glass has been damaged or broken it is highly recommended that you contact a qualified service person. Remove the broken pieces (be sure to wear gloves) and remove door. See the replacement parts list, at the end of the manual, you will require one 5 mm tempered glass panel with gasket installed.
  • Page 34 3.3.8 INITIAL FIRING When lit for the first few times, the appliance may emit an odor resulting from evaporation of paint and lubricants used in the manufacturing process. Open a door or window for ventilation. Anyone with a respiratory condition may need to leave the room during the initial firings. It is normal for the appliance to expand and contract while it heats up or cools down whether this is from a cold start or a steady-state condition where the fan has come on or off.
  • Page 35 Set Screw Air tube and Air shutter shown removed for clarity purposes only. 6/. Reassemble the fireplace in reverse order from 3 through 2. / Remonter la cheminée dans l'ordre inverse de 3 à 2. 7/. Turn on the gas. / Allumez le gaz. PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT.
  • Page 36 3.3.12 FAN ACCESSIBILITY / FAN ACCESSIBILITÉ (OPTIONAL) TURN THE MAIN GAS & POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE, VOTRE FOURNISSEUR DE 1/.
  • Page 37 4/. Once removed from the wall the fan will slide out through the opening. / Une fois retiré du mur que les fan vont glisser par l'ouverture. 5/. To replace fan and reassemble the fireplace go in reverse order from steps 4 through 1. / Pour remplacer les fan et montons la cheminée aller dans l'ordre inverse des étapes 4 à...
  • Page 38 2/. Undo the screws on the valve mount brackets at either end of the valve. / Défaire les vis sur les supports de montage robinet à chaque extrémité de la vanne 3/. Carefully tilt the valve through the opening and lift out of firebox for accessibility. / Soigneusement incliner la valve à...
  • Page 39 4.3 GLASS CLEANING The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air. For best results, use a ceramic glass cleaner or polish. Use a cleaner suitable for ceramic glass (e.g. cerama bryte stove cleaner). Avoid the use of ammonia based cleaners such as Windex ®...
  • Page 40 5.0 TROUBLE SHOOTING - INTERMITTENT PILOT SYMPTOM CORRECTIVE ACTION POSSIBLE CAUSE I. Pilot will not light after A. No spark at electrode (weak or not heat source for pilot ignition) repeated triggering of the remote control – intermittent pilot 1. Improper ignition 1.
  • Page 41 4. Defective wiring or connections 2. Conduct a test with a jumper wire and repair as required 5. Defective Valve 3. Contact service technician Soot deposits 1. Air inlet blocked or restricted Clean air inlets 2. Vent system is restricted or 2.
  • Page 42 6.0 REPLACEMENT PARTS When requesting service or replacement parts for your unit, please provide model name and serial number. All parts listed below may be ordered from an authorized dealer. Description Part# Certification Door Burner IMC1057A CSA/UL Door Glass ASTM C1048 Restrictor Door Glass Gasket Pilot Assembly (Standing pilot)
  • Page 43 7.0 INCA METAL CUTTING’S WARRANTY PROTECTION FOR ALL INCA METAL CUTTING GAS FIREPLACE PRODUCTS Inca Metal Cutting’s products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak tested and test fired at a quality control test station.
  • Page 44 CONDITIONS AND LIMITATIONS (continued) Notwithstanding any provisions contained in this warranty, Inca Metal Cutting’s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages. This warranty defines the obligations and liability of Inca Metal Cutting with respect to the Inca Metal Cutting gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
  • Page 45 CONDITIONS ET LIMITES (SUITE) doit être faite en conformité avec les instructions d'installation incluses avec le produit et toutes les capacités locales et nationales et de prévention des incend Cette garantie limitée ne couvre pas les dommages causés par une mauvaise utilisation, manque d'entretien, accident, des altérations, des abus ou de négligence.
  • Page 46 8.0 LABEL INFORMATION Page 46 of 53...
  • Page 47 8.0 LABEL INFORMATION (continued) Sections of the venting system have not been installed. WARNING – Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer’s instructions. Des sections du système d’évacuation n’ont pas été installées. AVERTISSEMENT - Ne pas utiliser l’appareil tant que toutes les sections n’ont pas été...
  • Page 48 APPENDIX A (AMERICAN FLAME VALVE INFORMATION) Page 48 of 53...
  • Page 49 APPENDIX A (Continued) Page 49 of 53...
  • Page 50 APPENDIX A (Continued) Special Features on the AF-4000 System The AF-4000 Module can be powered two different ways. The first is a standard 110 volt AC to 6.0 volt DC adaptor. This adapter is connected to the AF-4000 Module by connecting the two 1/4” female terminals from the adapter to the two 1/4”...
  • Page 51 APPENDIX A (Continued) AF-4000 Wiring Diagram APPENDIX B (NG – LP CONVERSION KITS) This kit will convert the fireplace to Natural Gas / Propane (as applicable). / Ce kit vous permet de convertir la cheminée au gaz naturel / propane (le cas échéant). The Elite models are designed to burn either natural gas or propane.
  • Page 52 8). Apply BL21ST-LP label plate over existing natural gas label plate and notify Savannah Heating of the serial numbers of both plates. (Original plate and replacement plate) / Appliquer plaque d'étiquette BL21ST LP-dessus de la plaque d'étiquettes existante de gaz naturel et de notifier savane chauffage des numéros de série des deux plaques.
  • Page 53 CONVERSION INSTALLATION / INSTALLATION DE CONVERSION ORIGINAL SERIAL PLATE #_____________________ REPLACEMENT SERIAL PLATE #____________________ This appliance was converted on DATE :_______________________________________ from NG / LP to LP / NG BY _____________________________________________________________________________________________ with the conversion kit NGCKBL21ST or LPCKBL21ST by the above named qualified service ageny/technician which accepts the responsibility that the conversion has been completed properly as per instructions in this manual.