Model BR70
PARTS COUNTING
When the scale is showing weight, pressing the
Before beginning, tare the weight of any container that will be used, leaving the empty container on the scale. Place the number of
samples on the scale. The number should match the options for parts counting, 10, 20, 50, 100 or 200 pieces.
Press the
key to begin. The scale will show "P 10" asking for a sample size of 10 parts. Change the sample size by pressing the
key, the display will cycle through the options: 10,20, 50, 100, 200 and back to 10.
Press the
key when the number matches the number of parts used for the sample. As more weight is added the display will show
the number of parts (pcs).
When in counting mode, you can press
Press the
key to return to normal weighing.
CHECK-WEIGHING
Check-weighing is a procedure to cause an alarm to sound when the weight on the scale meets or exceeds values stored in memory.
The memory holds values for a high limit and a low limit. Either limit can be used or both can be used.
See PARAMETERS SECTION for the procedure to be used to set the limits, function "F0 H-L" is used. After limits have been set the
Check-weighing function is enabled.
When a weight is placed on the scale the arrows will show if the weight is above or below the limits and the beeper will sound as
described below.
BOTH LIMITS SET
The display will show OK and the beeper will sound when the weight is between the limits.
LOW LIMIT SET
High limit is set to zero.
The display will show OK and the beeper will sound when the weight is less than the Low Limit. Above the Low Limit the display will
show HIGH and the beeper will be off.
HIGH LIMIT SET
Low limit is set to zero.
The display will show LOW and the beeper will be off when the weight is less than the High Limit. Above the High Limit the display
will show OK and the beeper will be on.
BOTH LIMITS SET. LOW IS SET GRATER THAN HIGH
The beeper will never sound and the display will show LOW if the weight is less that the Low limit, and HIGH if the weight is greater
than the Low Limit.
Note: The weight must be greater than 20 scale divisions for the checkweighing to operate.
To disable the Check-Weighing function enter zero into both limits by pressing the
pressing
to store the zero values.
Indicator
key will start the parts counting function.
key to show unit weight, total weight and quantity (pcs).
key when the current limits are shown then
User's Guide
23