STANDARD LIFT TABLE
OPERATING ISSUE
Does not reach the full
lift height.
The table rises then
descends.
The table board does
not descend.
Oil leakage at firing pin.
Oil leakage at pump.
Table will not rise.
Figure 1
Cable
with Boot
PAGE 1 OF 3
1-800-295-5510
uline.com
TROUBLESHOOTING
CAUSES
Steel ball of the check-valve is not fully
seating.
Firing pin does not allow the steel ball to
fully seat.
Low hydraulic oil.
Steel ball of the check-valve is not fully
seating.
Firing pin does not allow the steel ball to
fully seat.
The travel of the firing pin is not enough
to open the steel ball.
The O-ring is damaged.
The seal ring is damaged.
Change hydraulic oil.
Cable may be disconnected.
Figure 2
Correct
Cable Insertion
Para Español, vea página 2.
Pour le français, consulter la page 3.
RECOMMENDATIONS
Clean the valve opening and replace
the steel ball.
Adjust the tension rate of the steel wire
connected to the hand lever to adjust
the seating of the firing pin.
Add hydraulic oil.
Clean the valve opening and replace
the steel ball.
Adjust the tension rate of the steel wire
connected to the hand lever to adjust
the seating of firing pin.
Adjust the tension rate of the steel wire
rope to make firing pin at suitable
place and apply lubricant to the pin.
Change the O-ring.
Change the seal ring.
1) Unscrew sealing screw with a wrench.
2) Lift the hand lever.
3) Twist off screw of the oil plug and fill
pump with hydraulic oil.
Ensure cable with silver sleeve is
terminating inside of nut.
(See Figures 1-3)
Figure 3
Incorrect
Cable Insertion
0524 TH-1783

Publicité

loading

Sommaire des Matières pour Uline H-1783-H-10622

  • Page 1 Para Español, vea página 2. Pour le français, consulter la page 3. H-1783, H-10622 1-800-295-5510 uline.com STANDARD LIFT TABLE TROUBLESHOOTING OPERATING ISSUE CAUSES RECOMMENDATIONS Does not reach the full Steel ball of the check-valve is not fully Clean the valve opening and replace lift height.
  • Page 2 H-1783, H-10622 800-295-5510 uline.mx MESA DE ELEVACIÓN ESTÁNDAR SOLUCIÓN DE PROBLEMAS PROBLEMA DE CAUSAS RECOMENDACIONES FUNCIONAMIENTO No alcanza la altura La bola de acero de la válvula de Limpie la abertura de la válvula y reemplace máxima de elevación. control no se asienta completamente.
  • Page 3 H-1783, H-10622 1 800 295-5510 uline.ca TABLE ÉLÉVATRICE STANDARD DÉPANNAGE PROBLÈME CAUSES RECOMMANDATIONS La table n'atteint pas la La bille en acier du clapet anti-retour n'est Nettoyez l'ouverture de la soupape et hauteur maximale. pas appuyée complètement. remettez la bille en acier.