Replace the hydraulic oil in the log splitter after every 150 hours of use. Take
following steps to replace it.
1. Make sure all moving parts stops and the log splitter is unplugged.
2. Unscrew oil drain bolt with dipstick to remove it.
3. Turn the log splitter on the motor side over a 3 liters capacity container to drain
the hydraulic oil off.
4. Turn the log splitter on the support leg side.
5. Refill fresh hydraulic oil at the volume as per the hydraulic oil capacity of a
particular model indicated in the specifications table.
6. Clean the surface of Dipstick on the oil drain bolt and put it back into the oil
tank while keep the log splitter vertically.
7. Make sure the level of the refilled oil is just between 2 grooves around the
dipstick.
8. Clean the oil drain bolt before thread them back. Make sure they are tightened
to avoid leakage before placing the log splitter horizontally.
Periodically check oil level to ensure it is between 2 grooves around the
dipstick. Upon lower oil level, oil refilling is required.
Warning: Never mix oil with general waste!
Used oil must be disposed of according to current regulations in the
country where the machine is used.
Sharpening the wedge
After using the log splitter for some time, sharpen the wedge of the log splitter
using a fine-toothed file and smooth any burrs or crushed area along the cutting
edge
DISPOSAL
Do not dispose of power tools into household waste! According the
European Guideline 2002/96/EC for Waste Electrical and Electronic
Equipment and its implementation into national right, power tools that
are no longer usable must be collected separately and disposed of in
an environmentally correct manner.
Never dispose the residual fluids into household waste too. It must be collected
separately and disposed of in an environmentally correct manner too.