Télécharger Imprimer la page

Nordpeis N-29T Manuel D'installation page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
TECHNICAL TABLE
Insert
Material
Surface treatment
Weight of insert
Draught system
Combustion system
Maximum fuel length
Flue outlet
Flue collar
*Alternative versions exist due to national requirements
Flue gas temperature at flue
connector
Flue gas mass flow
Draft at flue connector
recommended
Data according to EN 13229:2001/A2:2004/AC:2007
Area of convection air vent under
insert
Area of convection air vent over
insert
Minimum distance conv. air outlet
to ceiling
Nominal heat output
Efficiency
CO (13% 0
)
2
Flue gas temperature
Draft
Fuel recommended:
Fuel length recommended
Fuel charge
Refueling interval
Opening of the air vent
control
Operating mode*
* Intermittent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember
Warning: If the requirements for ventilation are
NOT complied with, the cooling airflow around the
product will be considerably reduced and
the product can overheat.
This can cause a fire.
12
N-29T
Steel
Ignition and air vent
control
166 kg
Ignition air vent control
and air vent control
Clean burning
50 cm
Top and back
Outer Ø 150 mm
279°C
8,9 g/s
14-25 Pa
500 cm²
700 cm²
550/750 mm
8,6 kW
81 %
<1500 mg/m³
232°C
12 Pa
Wood logs
35 cm
2 kg
45 minutes
28 mm
Intermittent*
GB
3. Safety distances
Firewall
Ensure that the minimum safety distances are fulfilled
(FIG 1).
When connecting a steel chimney to the top outlet use
the security distances required by the manufacturer.
Important! When placing the insert on
a combustible floor, a steel plate of at least
0.7mm must cover the entire floor surface inside
the surround. Any flooring made of combustible
material, such as linoleum, carpets etc. must be
removed from underneath the steel plate.
The insert expands when in use, and for
this reason the surround must NEVER rest
on the insert, but have a gap of about 3 mm.
The insert must neither rest on the bench plate or
against the sides. It is recommended to dry stack
the surround in order to adjust the insert prior
to perforating the chimney for the flue connection.
4. Assembly
Removing the insert from the pallet FIG 2
Before the insert is removed from the pallet, remove the
accessories in the combustion chamber.
Attention! Our inserts are prepared for connecting
the smoke pipe on the outside of the flue collar Ø150.
*Alternative versions of the flue collar exist due to
National requirements. For the flue connection to the
chimney, follow the recommendations from the chimney
manufacturer.
Operational control
When the insert is in upright position, and prior to
mounting the surround, control that all functions are easy
to maneuver and appear satisfactory.
Nowy widok
FIG A
A. Air vent control
Left position = closed
Right position = open

Publicité

loading