All manuals and user guides at all-guides.com
Risk of Electrical
Shock. IMPROPER
GROUNDING CAN RESULT IN
ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed
by a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified
electrician.
Extension Cords
If an extension cord must be used, be
sure it is:
•
a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product
•
in good condition
•
no longer than 50 feet
•
16 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 14, 12, 10, and 8
AWG may also be used.
D29496
Voltage and Circuit Protection
Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
Certain inflators can be operated on a
15 amp circuit if the following
conditions are met.
1.
Voltage supply through branch
circuit is 15 amps.
2.
Circuit is not used to supply any
other electrical needs (lights,
appliances, etc.).
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15
amp circuit breaker or 15 amp
time delay fuse. NOTE: If inflator
is connected to a circuit
protected by fuses, use only time
delay fuses. Time delay fuses
should be marked "D" in Canada
and "T" in the US.
If any of the above conditions cannot
be met, or if operation of the inflator
repeatedly causes interruption of the
power, it may be necessary to
operate it from a 20 amp circuit. It is
not necessary to change the cord set.
10- ENG