When installing the appliance it is necessary to follow and comply with the following regulations:
-
current regulations on the matter;
-
any hygienic-sanitary regulations concerning cooking environments;
-
municipal and/or territorial building regulations and fire prevention prescriptions;
-
current accident prevention guidelines;
-
electricity board regulations concerning safety;
-
the regulations of the electrical power supply company or agency;
-
any other local prescriptions.
-
The room in which the appliance is to operate must be well ventilated.
-
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can be removed rapidly and
continuously.
-
Current regulations require the installation of a multiple pole switch between the appliance and the electrical power supply; the
switch must have a contact gap of least 3 mm on each pole.
-
This appliance requires two water connections: one for hot and one for cold water. Each line must be fitted with an on-off valve.
-
The electrical isolating switch and the water shutoff valves must both be located near to the appliance, within easy reach
for the user.
-
Remove all the packaging and check that the appliance is in perfect conditions. In case of visible damage, do not connect the
appliance and notify the sales point immediately.
-
Remove the PVC protection from the panels.
-
Dispose of packaging according to regulations. Generally material is divided according to composition and should be delivered to the
waste disposal service.
-
There are no special instructions regarding distances from other appliances or walls, however it is advisable to maintain a sufficient
distance to allow any servicing operations to be performed. In the event the appliance should be installed in direct contact with
inflammable walls, it is advisable to fit a suitable heat insulation.
-
The appliance must stand level. Small differences in level can be eliminated by screwing or unscrewing the adjustable feet: A
significantly uneven or sloping stance can affect the operation of the appliance adversely.
-
Before connecting any parts of the appliance to supplies, make sure that the latter is equivalent the requirements stated
in the technical data plate, if the appliance has been designed for these supplies.
-
Only qualified technicians must perform the installation, maintenance and test of the appliance.
-
The appliance is supplied to operate according to the power supply indicated on the data plate.
-
As mentioned, the appliance must be connected to the power supply by way of a multiple pole main isolating switch and protection
device, that must be proportioned to the power of the appliance (1 mA per kW of rated power).
-
The earthing system must be efficient.
-
As this appliance is a type X equipment (delivery without power cable and plug), the cable and other hardware needed to make the
connection to the electrical power supply must be provided by the installer.
-
The power cable shall be of the kind described in the paragraph "Technical data" and shall be resistant to oil.
-
Proceed as follows to reach the power supply terminal board:
-
Disconnect the appliance using the switch placed before the appliance.
-
Remove the fron panel, unloosing the two fixing screws.
-
The cable must be fed in from beneath the clamp. The individual wires are then fastened to the corresponding terminals of the
terminal board. The earth wire must be longer than the other wires, so that in the event of the cable being jerked or the clamp
broken, the live wires will disconnect first. Lock the cord fastener.
-
The appliance must incorporate an equipotential system.
-
Connect the terminal on the lower right-hand side marked with the international symbol a connector with a nominal cross section <10 mm
the appliances installed and the earth system of the building shall be connected like this.
BS80FE7 / BS80IE7
LAWS, TECHNICAL PRESCRIPTIONS AND DIRECTIVES
Special requirements for the installation site
ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING
POSTIONING
INSTALLATION