Télécharger Imprimer la page

Berker DOMINA Serie Manuel D'instructions page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
7-8, using a soft, spongy cloth
and a semi-rigid nylon brush
for the sharp areas of the plate
and the product holder. Do not
clean the machine with jets of
water or steam or similar meth-
ods. DO NOT DISHWASH.
Cleaning the sliding meat ta-
bles models SLL 315-350-370,
SLH 315-350-370
- SLL 315-350-370: pull the
sliding meat table to the end;
a metallic click notifies the
operator that the meat table
is locked. Lift the meat table all
the way up (Fig. E-1). Clean the
sliding meat table and repeat
operations in the reverse order
to reposition the sliding meat
table.
- SLH 315-350-370: loosen,
rotating the product presser
clamp on the meat table in the
anticlockwise direction. Pull
the sliding meat table to the
end; a metallic click notifies the
operator that the meat table is
locked. Move the sliding meat
table away from the thickness
gauge plate and lift the product
presser (Fig. F-1). Clean the sli-
ding meat table and lower the
product press holder. Lift the
sliding meat plate and clean
the meat table (Fig. F-2). Rele-
ase the meat table, rotating the
product presser clamp in the
clockwise direction.
Removing the meat table (SLG
315 - 350 - 370)
- with the regulating knob for
slice thickness (3) in the safety
position (Fig. A, Fig. D-1), pull
back the plate support (6) all
the way until the travel limit
toward the operator (Fig. D-2);
- fully rotate the locking knob
in the anticlockwise direction
(Fig. D-3) keeping the support
at the travel limit, until the
safety locking device inter-
venes on the gauge plate;
- remove the meat table from
the top, sliding it off from the
support.
WARNING! Make sure
!
that the product press
holder is lowered on the table
before removing the plate sup-
port.
!
WARNING! Keep the reg-
ulating knob for slice thick-
ness in the safety position "0".
Removing the product press
holder (SLG 315 - 350 -370)
rotate the grip and remove the
product press holder (Fig. G).
Removing the blade cover (11)
- rotating in the anticlockwise
direction, loosen the blade cov-
er tension rod grip (19);
- press the tension rod grip
and raise the blade cover to re-
move it.
WARNING! Once the
!
blade cover has been re-
moved, an interlocking device
stops the blade rotation.
Removing the slice deflector
(20)
For Gravity versions SLG 315
- 350 - 370: loosen the locking
pin and rotate the slice deflec-
tor downward to remove it
from the pin.
Loosen the fixing screw(s) and
remove the slice deflector.
Sharpener (12)
Clean the body with a damp
cloth. Do not submerge in water.
Cleaning:
- the blade: press a damp cloth
on the surface of the blade and
move it slowly from the center
toward the outside on the
12
blade cover side and the oppo-
site side. In the same way dry it
using a dry cloth. NEVER turn
on the machine while cleaning
the blade;
- the safety ring: use a soft
brush to clean the area be-
tween the blade and the safe-
ty ring. Be careful NOT to put
your hands close to the blade;
- the machine body: use a damp
cloth or a sponge. Dry carefully;
- the sharpener: 1) clean the
body with a damp cloth and the
springs with a semi-rigid brush.
2) do not submerge the sharp-
ener in water. The sharpening
wheel can easily be removed
from the sharpening unit, re-
moving it in the direction of the
arrow (Fig. I). Keep the wheel
clean for correct sharpening.
Remove dirt and grease with
alcohol and a semi-rigid nylon
brush.
WARNING!
!
dismantled parts indivi-
dually in lukewarm water and
NON-AGGRESSIVE
sher detergent, using a bottle
brush or cloth. Rinse in hot wa-
ter and dry.
Proceed with assembly opera-
tions, following the directions
described in reverse order.
REMOVING THE BLADE
WARNING! Use original
!
devices only!
WARNING! Danger of
!
being cut! Use only after
carefully reading the operating
instructions supplied with the
device.
If a blade removal device has
been purchased, it is recom-
mended that you follow the
Clean
all
dishwa-

Publicité

loading