Alarms:
The control will alert you to conditions that could adversely
affect the performance of the appliance.
Door Ajar
Door ajar -
If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK
indicator will turn-off, the "Door Ajar" indicator will flash,
and a tone will sound every 60 seconds. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad. This alarm condition can be reset
by closing the door or momentarily pressing the "On/
Off" keypad, (i.e.-if you are cleaning the storage com-
partment, etc.). The alarm will recur in 5-minutes if the
alarm condition persists.
Power Failure
Power failure -
If power to the appliance is inter-
rupted the System Status indicator will turn-off and
the "Power Failure" indicator will flash. Additionally, an
"ALARM RESET" indicator will be displayed below the
"On/Off" keypad. No audible tone will sound. This alarm
condition can be reset by momentarily pressing the
"On/Off" keypad. If this alarm occurs, it is recommend-
ed that you check the condition of any perishables,
even if the appliance is operating normally and the tem-
perature has recovered, as prolonged power outages
could result in excessive temperature excursions which
may spoil perishables.
USING YOUR ELECTRONIC CONTROL
ALARM RESET
ALARM RESET
Temp
Temperature alarm -
temperature exceeds 10°F from set-point for more than
a 1-hour duration, the System Status indicator will turn
off, the "Temp" indicator will flash, and an audible tone
will sound every 60-seconds. Additionally, an "ALARM
RESET" indicator will be displayed below the "On/Off"
keypad. This alarm condition can be reset by momen-
tarily pressing the "On/Off" keypad. If this alarm occurs
it is recommended that you check the condition of your
stored contents, even though the appliance is operating
normally and the temperature has recovered, as pro-
longed temperature excursions could spoil perishables.
NOTE
Multiple alarms are possible, i.e.- "Door Ajar" for a pro-
longed period may trigger a "Temp" alarm, in which case
both "Door Ajar" and "Temp" indicators will activate.