Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
10.7
Loading the product
Energise the cabinet to start its cooling cycle,
by acting on the general disconnector switch
mounted on the wall. After about 2 hours it is
possible to load the cabinet.
The cabinet is suitable to maintain the
temperature of the goods and not lower it; the
foods, therefore, must be introduced inside it
only if already cooled to the respective
temperatures of preservation. Products which
have been heated must never be introduced
into the cabinet.
In loading the goods, ensure that:
• The load is homogeneous in terms of
dimension and quality of the products
• The goods do not obstruct the correct flow
of refrigerated air ("Fig. 22")
• For good product preservation, always
keep approx. 10 cm distance from the
upper part of the door compartment.
F
MAXIMUM ANGLE OF DOOR OPENING =
110°. For correct operation and to avoid
any structural failure and/or problems,
you need to avoid force opening the
doors at an angle over 110°.
Uniformly distributed maximum permissible
load: 32 Kg .
10.8
Access
Information for access
The EptaBricks model has EPTA software
installed on each collection point.
This manual describes access to the software
via:
• Client profile
• Delivieres operator profile
Each profile has rights, therefore different
menu displays are required.
Warning! The door lock is equipped with a
magnetic stop; if the door is opened, opening is
signalled with an alarm.
Doc. n° UM000648 | Rev. A | 13/01/23
EPTABRICKS 2.0 OUTDOOR
Epta Spa - Via Mecenate, 86 - 20138 Milano (MI) ITALIA
Tel. 02/55403211 Telefax 02/55401023
Client profile - Product collection
The MASTER column allows collection of orders,
both using scanning/entering the order number
and scanning/entering the loyalty card.
For the loyalty card, if the client has multiple
orders in the doors, a specific screen will appear
with the list of orders which can be collected.
The doors open one by one; to open the next
door, you need to close the previous one.
At the end of collection, the client has the
possibility of:
• Finishing collection then returning to the
initial screen.
• Opening the doors again (if the client is
unsure whether an item was forgotten).
If a problem occurs during resetting, an
appropriate message will be displayed for the
client.
• Access product collection by pressing the
central, white key.
19/27
User manual
IT
FR
EN
EN
DE
ES
PT
Fig. 34
19