2. Terminal Explanation
2-1. DRF960
+V
DRF960-24-1
L
DC OK
+V
-V
-V
24VDC/40A
V.ADJ
DC OK
PEAK
240VAC
N
1
+V: +Output terminal
2
- V: - Output terminal
3
V.ADJ: Output voltage adjust trimmer
The output voltage rises when trimmer is
turned clockwise.
4
L: AC Input terminal
Live line (fuse in line)
5
N: AC Input terminal
Neutral line
6
: Protective Earth
Connect to safety ground of apparatus
or equipment.
7
DC OK : Green LED lights when Output
Voltage on and within specification
8
PEAK : Red LED lights when Output
Current peaks
9
DC OK: Relay contact
DC OK : Relay contact
Signal Connector – see section 12
A
WIRING
CONNECTOR
Recommended Wire
INPUT
10~24 AWG
(L, N,
)
OUTPUT
6~20 AWG
(+V, -V)
OUTPUT
10~24 AWG
(DC OK)
Note: According to EN/UL60950-1 multi-
strand flexible cables connected to the input
require ferrule.
TDK-Lambda
DRF960 Series
INSTRUCTION MANUAL
Max. Torque
10.3 kgf.cm
(9 lbf.in)
23 kgf.cm
(20 lbf.in)
10.3 kgf.cm
(9 lbf.in)