Technical data
Rated voltage
Weight in accordance with EPTA Procedure 01
Crimping / pressing time
Max. crimping / pressing force
Max. cutting capacity (NCT J ACSR cutting jaw)
max. cutting capacity (outside diameter)
(NCT J CUAL cutting jaw)
Max. permissible crimping capacity
Storage temperature
Ambient temperature for operation
4.1
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise values
Sound power level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration values
Total vibration (during operation) (a)
Uncertainty (K)
4.2
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
*2321736*
)
)
WA
)
pA
)
pA
2321736
Guy Wire EHS
Steel-reinforced Al ca-
ble (ACSR)
Cu/Al cable
Cu cable
Al cable
Cu cable
Al cable
Cu cable, fine strand
21.6 V
See the end of these operating
instructions
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
−10 ℃ ... 45 ℃
21.6 V
1.7 kg
≈ 4 s
53 kN
7.1 mm
20.6 mm
23.8 mm
31.8 mm
33 mm
240 mm²
240 mm²
185 mm²
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
77 dB(A)
2.5 dB(A)
66 dB(A)
1.5 dB(A)
< 2.5 m/s²
1.5 m/s²
English
23

Publicité

loading