2.5. Setting the production setpoint
Possible settings: from 00 to 10, in increments of 1.
Default setting: 10.
Select a production setpoint using the top key (no confirmation required).
2.6. Boost mode (optional)
Boost mode sets the production value to its maximum for 24 hours but can be stopped at any point. This function is
used when chlorine is urgently needed.
I
Boost mode cannot replace a conventional shock treatment in the case of water not fit for bathing.
Boost mode continues after powering off the electronics unit.
When the Boost mode terminates or stops, production continues according to the initial setpoint.
Switching on: Press the bottom button: the message bo appears.
Switching off: Press the top button.
2.7.
The socket marked
or an external control, or a cover position switch.
2.7.1. Pre-configuration
I
This configuration must be carried out.
1) Press and hold down the bottom key, until the message In is displayed.
2) Press on the top key x times until the message CG is displayed.
3) Press the bottom key (one of the following displays will flash).
4) Using the top key, move to position:
- CF, for connection to a flow sensor
- CE, for connection to an external control
- Co, for connection to a cover position switch
- oF to disable the
5) To confirm, press the bottom key: the display freezes for a moment.
2.7.2. Production operation depending on the type of element connected
If flow sensor or external command (default configuration in NO switch):
- When the switch is activated, production follows the setpoint as shown on the screen.
- When the switch is not activated, production is stopped. The message oF appears.
If cover position switch (default configuration in NO switch):
- When the switch is activated, production is reduced by 25% in relation to the setpoint. The message Co appears.
- When the switch is not activated, production follows the set point as shown on the screen.
To switch from a NO switch (normally open) to an NC switch (normally closed), or vice versa:
a) Carry out steps 1 to 4 above.
b) Press and hold down the 2 keys: the current switch flashes nO or nC.
c) Using the top key, select an nO or nC switch.
d) Confirm with the bottom key: the display freezes for a moment.
(optional)
or
(depending on the model of the electronics unit) is used to connect a flow sensor,
socket (default setting).
4