M1297-0_dratft-03
The exhaust pipe
For the drain connect a 14mm internal diameter
rubber hose to the connection D on the lower-left
side of the frame.
Pic.6 – The water drain
C
To ensure proper drainage of water make
sure that the drain hose is sloped and well
laid out, with no elbows or narrowing of
any kind.
The control panel
S1 - Green light ON The green light indicates when
the dehumidifier is operative, otherwise it blinks on
status 0 (powered but off).
S2 - Red light, full tank The light blinks, together
with the green one S1, when the tank is full, missing
or incorrectly positioned.
S3 - Yellow light, defrost The light switches on dur-
ing the automatic defrosting cycle.
T1 - Decrease button Pushing this button will de-
crease the value of the display D down to 0.
T2 - Increase button Pushing this button will in-
crease the value of the display D up to C.
D - Display The display shows the working state of the
dehumidifier according to the table below (Tab.C).
The value 0 means OFF, from 1 to 9 means automatic
functioning and is controlled by the humidistat that
switches the dehumidifier on or off if the value of
the relative humidity is higher or lower than the one
shown in Tab.C. The value C means ALWAYS ON
and the dehumidifier works independently from the
humidity value: nevertheless, any alarm has priority
over the functioning mode.
Display
0
1 ÷ 2
3 ÷ 4
5 ÷ 6
7 ÷ 8
9
C
Failures
The display is used by the electronic device to show
particular situations (Tab.D) If an error message is
displayed please contact your dealer for repair.
Display
n
u
ENGLISH
Pic.7 – The control panel
Functioning
from about 85% to 90% R.H.
from about 70% to 80% U.R.
from about 60% to 65% R.H.
from about 45% to 55% R.H.
about to 40% R.H.
Tab.C – Functioning modes
Description
Temperature probe must be checked
Humidity probe must be checked
Tab.D – Error messages
Off
Continuous
15